PACSystems RXi IPC QSG

  

 

 

GFK-2784J

 

 
 
 

Warning 

If the Box IPC is operating in ambient temperatures greater than 50°C (122 °F), its exterior temperatures may 

be too hot to touch safely. To avoid burn hazards, the unit must be installed in a 

restricted access area

, as 

defined by: 

 

Access can only be gained by 

service persons

 or by 

users

 who have been instructed about the reasons for the 

restrictions applied to the location and about any precautions that shall be taken; and 

 

Access is through the use of a tool or lock and key, or other means of security, and is controlled by the authority 
responsible for the location. 

 

Caution 

EMC Requirements 

When installing, operating, or maintaining the RXi Box IPC, personnel must insure any electrostatic charge is 

discharged through the use of a grounded ESD strap or other means. 

 

Quickstart 

 

Upon receiving the RXi Box IPC, carefully inspect all shipping containers for damage. If any part of the system is damaged, notify 
the carrier immediately. The damaged shipping container should be saved as evidence for inspection by the carrier. 
As the consignee, it is your responsibility to register a claim with the carrier for damage incurred during shipment. However, we 
will fully cooperate with you should action be necessary. 
After unpacking the RXi Display, 

record all serial numbers

. Serial numbers are required if you need to contact Customer Care 

during the warranty period. All shipping containers and packing material should be saved should it be necessary to transport or 
ship any part of the system. 

Note:

 

For phone numbers and email addresses, refer to the section, 

Contact Information

Verify that all components of the system have been received and they agree with your order. If not, contact Customer Care. For 
technical help, contact Technical Support. 
Before attempting to power up the RXi Display for the first time, inspect the unit for loose or damaged components. If damage is 
observed (such as bent component leads or loose components), contact GE. Depending on the severity of the damage, it may be 
necessary to return the product to the factory for repair. 
Before you attempt to power up the RXi Box IPC for the first time, inspect the unit for loose or damaged components. If damage 
is observed (for example, in the form of bent component leads or loose components), contact GE  for additional instructions. 
Depending on the severity of the damage, it may be necessary to return the product to the factory for repair 

Note:

 

Do not

 apply power to the unit if it has visible damage. Applying power to a unit with damaged components may 

cause additional damage. 

 

Installation 

The IPC can be mounted on a DIN-rail or panel-mounted using the ICRXIACCBPL Backplate (ordered separately). You can also 
mount the IPC directly onto a panel (without a Backplate). 
The IPC has four captive machine screws in its base for attaching the unit to the Backplate or panel. 
For installation guidelines and procedures, including required clearances for heat dissipation, and connection details refer to the 

PACSystems RXi Box IPC User Manual (GFK-2785)

Manuals can be downloaded from the Support website at 

http://support.ge-ip.com. 

 

 

Summary of Contents for PACSystems RXi ICRXIBN7E001A

Page 1: ...rnal disks provide highly reliable local long term data retention USB and SD Card interfaces enable program loading serial communications and removable data storage through standard devices Ordering I...

Page 2: ...mental Specifications Note The Box IPC should be installed in a location that is not exposed to corrosive gases or liquids rain or direct sunlight and meets the environmental specifications listed in...

Page 3: ...should it be necessary to transport or ship any part of the system Note For phone numbers and email addresses refer to the section Contact Information Verify that all components of the system have be...

Page 4: ...damage has been caused by incorrect transportation operating storage conditions or handling To power up the unit press the Power On Off switch for at least second If you notice any damage remove powe...

Page 5: ...o shut down the IPC 1 Press the Power On Off switch briefly between 100 ms and 4 sec or select Shut Down from the Windows Start menu This provides a controlled shutdown of the operating system before...

Page 6: ...Connector Indicators Connectors Blue blinking Booting Blue slow fade S3 Sleep Green solid Running Red solid Fault R e s e r v e d R e s e r v e d R e s e r v e d S A T A D r i v e S t a t u s O v e r...

Page 7: ...CPI Sleep State is S1 CPU Stop Clock The default settings send IPC to sleep state S1 The ring LED stays green while the IPC is in Sleep State S1 The ring LED fades blue while the IPC is in Sleep State...

Page 8: ...Customer Care Email customercare ip ge com Primary language of support English Europe the Middle East and Africa Online Technical Support http support ge ip com Phone 800 1 433 2682 EMEA Direct Dial...

Reviews: