– 58 –
(
Continued next page
)
Note:
The water tank and the tank inlet and outlet
tubes are replaced as an assembly. The tank inlet
and outlet tubes are routed through separate
conduits placed inside the cabinet wall.
9. Place the top table upsidedown on top of the
cabinet. (See
Top Table
.)
10. Push in the rear collar on the water coupling
then pull out the water tube.
11. Remove the machine compartment cover. (See
Machine Compartment Cover
.)
12. Remove the Phillips-head screw that holds the
water valve in place.
Rear Collar
Water Coupling
14. Carefully pull out the water tank and remove the
tubing from the conduits.
13. Push in the collar on the dispenser side of the
valve then pull out the water tube from the valve
assembly.
Collar