Dimensions and Installation Information (in inches)

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service, 

800.626.2000.

PP932TM/KM/BM

GE Profile

™ 

30" Built-In CleanDesign Electric Cooktop

 

220585

Listed by 

Underwriters 

Laboratories

Note:

 Check local codes for required breaker size

Important:

 Requires a 5" free area between the 

bottom of the cooktop to any combustible material, 
i.e., shelving. Free area not required when installing 
wall oven underneath cooktop. Refer to installation 
instructions. Requires a 15" minimum from cooktop to 
adjacent overhead cabinets. Units are furnished with a 
48" flexible armored cable. 

Note:

 30" Ribbon cooktops are approved for use over select GE 27" and GE 30" 

Single Wall Ovens and Warming Drawers. Refer to cooktop and wall oven/ 
warming drawer installation instructions packed with product for current  
dimensional data. If installed with a GE Profile

™ 

Telescopic Downdraft System, 

consult both the cooktop and downdraft installation instructions packed with 
product before installing. Cooktop gas/electric supply may need to be re-routed 
to install downdraft. Consult cabinet and countertop manufacturer’s specs for 
flush mount installation prior to install. 

Before installing, consult installation 

instructions packed with product for current dimensional data.

 

Filler Trim Kit:

 When replacing an old GE 30" cooktop (with larger opening)  

use the following one-piece trim kit to fill in the over-size hole. Available at  
additional cost. JXTR32W (True White) JXTR32B (Black glass) JXTR32C  
(True Bisque)

KW Rating

240V

8.6

208V

6.5

Breaker Size

240V

40 Amps

208V

40 Amps

3-1/4*

Cooktop

2-1/2**

Required

28-1/2

19-5/8

29-3/4

30_color_cktp_install.eps

21-3/8

Electrical junction box 16" MIN. 

below countertop

30" MIN. to

unprotected

cabinet

Cut should 

not interfere 

with cabinet

structure 

at front

1-1/2" MIN.

clearance to

side wall

from cut-out

1-1/2" MIN.

clearance to

side wall

from cut-out

1-3/4" to

rear wall

13" MAX.

depth

  * Depth of unit at conduit connection location (rear) is 

6-1/2" on models PP980/975/950/945 and 4-5/8" 

on models PHP900/PP972/962/942/932/912, 

JP655/356/346.

 **Raised bull nose countertops may require up to 

3/8" additional clearance to prevent interference 

with curved front.

15" MIN.  

to cabinet

Specification Revised 12/07