For complete information, see installation instructions packed with your dryer.
Ducting Materials:

 

For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If 

rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit 

WX08X10077). In special installations, it may be necessary to connect the dryer to the house vent 

using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil-type) duct may be used ONLY 

in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where 

a 4” diameter can be maintained throughout the entire length of the transition duct. Please see 

installation instruction packed with your dryer for complete instructions when using flexible metal 

(foil type) ducting. 

Exhaust Length Calculation:

 

1.  Determine the number of 90° turns needed for your installation. If you exhaust to the side or 

bottom of dryer, add one turn.

2.  The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown 

in the table. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be 

treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.

Dryers 

must

 be exhausted to the outside.

Caution:

 For personal safety do not terminate exhaust into a chimney, under any enclosed 

house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or 

moisture could cause damage. Never terminate the exhaust into a common duct or plenum with 

a kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, 

etc. The wall cap must also be located at least 12" above the ground or any other obstruction 

with the opening pointed down.
Dryer Elbow Kit, Pub. No. 14-A003 is available at additional cost. For use with side or bottom 

exhaust options.

For more information on venting kits and accessories, please call 1-800-GE-CARES.

270194

DPGT650EH 

GE Profile

 High-Efficiency Electric Dryer

 

Specification Revised 5/09

Summary of Contents for Profile DPGT650EH

Page 1: ...ch circuit protected by a 30 amp circuit breaker or a time delay fuse is required Electric Dryer Rating 240V 6000W 28 5A 60Hz Note Dryer wall outlet must be located within 36 of service cord entry and accessible when dryer is mounted in position Installation Information For complete information see installation instructions packed with your dryer Dimensions and Installation Information in inches 2...

Page 2: ... The maximum length of 4 rigid aluminum or galvanized duct which can be tolerated is shown in the table A turn of 45 or less may be ignored Two 45 turns within the duct length should be treated as a 90 elbow A turn over 45 should be treated as a 90 elbow Dryers must be exhausted to the outside Caution For personal safety do not terminate exhaust into a chimney under any enclosed house floor crawl ...

Page 3: ...um of 60 sq in of open area equally distributed If this closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed No other fuel burning appliance shall be installed in the same closet with a gas dryer Bathroom or Bedroom Installation The dryer MUST be exhausted to the outdoors The installation must conform with the local codes or in the ab...

Page 4: ...e fabric temperature of 125 degrees F to protect fine handwashables Stainless Steel Drum Resists rust and won t chip peel or snag clothes 5 Heat Selections Offer enhanced drying performance and fabric care Multiple Dry Cycles Deliver optimal drying results Adaptive Cool down Tumbles clothes with cool air to reduce wrinkling Speed Dry Delivers ready to go results in minutes Wrinkle Care Extended Tu...

Reviews: