background image

Dimensions and Installation Information (in inches) 

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

270194

DPGT650EH 

GE Profile

 High-Efficiency Electric Dryer

 

Listed by 

Underwriters 

Laboratories

Specification Revised 5/09

Special Installation Requirements
Alcove or Closet Installation:

 

• 

If your dryer is approved for installation in an alcove or closet, it will be stated on a label  

  on the dryer back. 

• The dryer MUST be exhausted to the outside.

 

•  Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:

 

0" either side; 3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.

 

•  Closet doors must be louvered or otherwise ventilated and must contain a minimum 

of 60 sq. in. of open area equally distributed. If this closet contains both a washer and 

a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors.

 

•  The installation must conform with the local codes, or in the absence of local codes, 

with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearances other than Alcove or Closet Installation:

•  Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
Dryer Exhausting Information : 

Use metal duct only, vertical and horizontal ducting.

Best performance

Domestic  

dryer models

Maximum length of 4"

dia. 

rigid metal 

duct

Number

of

90°

turns

Exhaust hood type

A

4" 

opening

B

2-1/2" 

opening

7.0, 6.0 and 5.8 cu. ft.

capacity models 

all electric dryers

4

90 ft.

60 ft.

45 ft.

35 ft.

25 ft.

60 ft.

45 ft.

35 ft.

25 ft.

15 ft.

A

4

B

2-1/2

A

Summary of Contents for Profile DPGT650EH

Page 1: ...ch circuit protected by a 30 amp circuit breaker or a time delay fuse is required Electric Dryer Rating 240V 6000W 28 5A 60Hz Note Dryer wall outlet must be located within 36 of service cord entry and accessible when dryer is mounted in position Installation Information For complete information see installation instructions packed with your dryer Dimensions and Installation Information in inches 2...

Page 2: ... The maximum length of 4 rigid aluminum or galvanized duct which can be tolerated is shown in the table A turn of 45 or less may be ignored Two 45 turns within the duct length should be treated as a 90 elbow A turn over 45 should be treated as a 90 elbow Dryers must be exhausted to the outside Caution For personal safety do not terminate exhaust into a chimney under any enclosed house floor crawl ...

Page 3: ...um of 60 sq in of open area equally distributed If this closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed No other fuel burning appliance shall be installed in the same closet with a gas dryer Bathroom or Bedroom Installation The dryer MUST be exhausted to the outdoors The installation must conform with the local codes or in the ab...

Page 4: ...e fabric temperature of 125 degrees F to protect fine handwashables Stainless Steel Drum Resists rust and won t chip peel or snag clothes 5 Heat Selections Offer enhanced drying performance and fabric care Multiple Dry Cycles Deliver optimal drying results Adaptive Cool down Tumbles clothes with cool air to reduce wrinkling Speed Dry Delivers ready to go results in minutes Wrinkle Care Extended Tu...

Reviews: