DPXH46GACC/WW—GE Profile

Extra-Large 5.7 Cu. Ft. Capacity Front-Load Dryer

Specification Revised 2/02

TM

Dryer Dimensions (in inches)

Exhaust Options:

When viewed from the front of the unit, exhaust 3-way via rear, right and bottom. Dryer is
shipped exhausted to the rear. Alternate exhausting knockouts are supplied. 

Gas Dryer Electric Rating: 

120V, 60Hz, 6A

An individual properly-grounded branch circuit, with a three-prong grounding-type receptacle,
protected by a 15 or 20 amp circuit breaker or a time-delay fuse is required.

Gas (BTU/HR): 

22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas supply

requires a conversion kit. Check installation instructions for correct kit and have a qualified
gas technician install a conversion kit. See dryer ducting information for proper installation.

Note: 

Dryer wall outlet must be located within 36" of service cord entry and accessible 

when dryer is mounted in position.

Installation Information: 

For complete information, see installation instructions packed

with your dryer.

R

Listed by
Underwriters
Laboratories

For answers to your Monogram,

® 

GE Profile

or 

GE appliance questions, visit our website at
GEAppliances.com or call 
GE Answer Center

®

service, 800.626.2000.

REAR VIEW

26-7/8

3-3/4

1

36

Under 

Counter

34-5/8"

3/16" 

Gas Pipe Connection

Electric 
Connection

2-9/16

13-9/16

SIDE VIEW

25-3/4

47-1/2

4-3/4

Optional
Vent Knockout

Door Open

90

°

4-3/8

3/4

Summary of Contents for Profile DPXH46GACC/WW

Page 1: ... supply requires a conversion kit Check installation instructions for correct kit and have a qualified gas technician install a conversion kit See dryer ducting information for proper installation Note Dryer wall outlet must be located within 36 of service cord entry and accessible when dryer is mounted in position Installation Information For complete information see installation instructions pac...

Page 2: ... must contain a minimum of 120 sq in of open area equally distributed The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line No other fuel burning appliance shall be installed in the same closet with the dryer Bathroom or Bedroom Installation The dryer MUST be exhausted to the outdoors The installation must conform with the local codes or in t...

Page 3: ...llation If you exhaust to the side or bottom of dryer add one turn 2 The maximum length of 4 rigid aluminum or galvanized duct which can be tolerated is shown in the table The maximum length for flexible ducts are less than for rigid duct A turn of 45 or less may be ignored Two 45 turns within the duct length should be treated as a 90 elbow A turn over 45 should be treated as a 90 elbow Exhausting...

Page 4: ... Features and Benefits Extra Large 5 7 cu ft Capacity Sensor Dry ColorLogic 2000 Tumble Drying 4 Temperature Options Regular Cottons Medium Permanent Press Low Delicates and Air Fluff No Heat Cool Down 1 Time Dry Cycle 3 Auto Dry Cycles Cottons Easy Care and Knits Delicates 2 Wrinkle Care Cycles Moisture Sensor Fixed End of Cycle Signal Quick Clean Lint Screen Drying Rack Spill Saver Top Interior ...

Reviews: