Specification Revised 9/04
220824
TM
JDP47BF/CF/WF – GE Profile
™
30" Drop-In Electric Range
Dimensions (in inches)
KW Rating
240V
11.6
208V
8.7
Breaker Size
240V
40 Amps
208V
40 Amps
R
Listed by
Underwriters
Laboratories
For answers to your Monogram,
®
GE Profile
™
or
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center
®
service, 800.626.2000.
Optional Kits For Drop-In Electric Ranges
(Available At Additional Cost)
Note:
Cabinets installed adjacent to drop-in electric ranges must have an
adhesion spec of at least a 194°F temperature rating.
Note:
All 30" Drop-In Radiant Ranges conform to U.L. requirements for 0"
spacing from range to adjacent walls below countertop. To reduce possibility
of scorching the side walls above the countertop when no load is present on
burners, it is recommended that a minimum 6" spacing from adjacent side
wall be allowed for possible extended high-heat element operation.
Installation Information:
Before installing, consult installation instructions
packed with product for current dimensional data.
IMPORTANT:
30" DROP-IN RANGES ARE DESIGNED TO HANG
FROM THE COUNTERTOP. IT DOES NOT REST ON THE FLOOR.
FOR INSTALLATION ALTERNATIVES, REFER TO INSTALLATION
INSTRUCTIONS PACKED WITH PRODUCT.
Maintop Filler
(Fills gap between cooktop and
wall when unit is installed in
30" free-standing cutout)
JXS66WW—White
JXS66CC—Bisque
JXS66BB—Black
Accessory Backguards
(Attaches to the back of range as
a backguard when unit is installed
in 30" free-standing cutout)
JXS37WW—White
JXS37CC—Bisque
JXD37BB—Black/Stainless
Lower Trim Kits
(When a drop-in is installed in an
existing cutout greater than 27-1/4"
from the counter to the cabinet
cross-rail, a lower trim kit should
be used to fill the gap at the
bottom of the range)
JXS96WW—White
JXS96CC—Bisque
Acceptable Electrical Outlet
Area Also In Adjacent
Cabinet Or Under Floor
Conduit is 40" long
Shave Raised Edge To Clear
31-1/8" Wide Control Panel
9/16
30" Min.
30" Min.
15" Min.
6" Min.
from walls
7-1/2
2-7/8"
To Front Surface
of Countertop
30
36
27-1/2
25
23-3/16
If necessary,
build upsides
to 1-1/4" thick
to provide
countertop
support
2000_drop_in.eps
26-1/2
27
20-5/8" Door
Clearance
From Front
Surface of
Countertop
24
31-1/4
30
A/B
Accessory
Backguard
Acceptable Electrical Outlet
Area Also In Adjacent
Cabinet Or Under Floor
Conduit is 40" long
Shave Raised Edge To Clear
31-1/8" Wide Control Panel
9/16
30" Min.
30" Min.
15" Min.
6" Min.
from walls
7-1/2
2-7/8"
To Front Surface
of Countertop
30
36
27-1/2
25
23-3/16
If necessary,
build upsides
to 1-1/4" thick
to provide
countertop
support
2000_drop_in.eps
26-1/2
27
20-5/8" Door
Clearance
From Front
Surface of
Countertop
24
31-1/4
30
A/B
Accessory
Backguard
an Anti-Tip device. The installation
of this device is an important,
required step in the installation
of the range.