– 52 –
Hook
Spring
Lever
Roller
Cam
Note:
Each door closer cam can be installed
incorrectly. Ensure each cam is installed on the
bottom of the drawer with the hooked end towards
the center of the drawer.
Bottom View of Drawer and Right Side Cam
Bottom of Drawer
Drawer Closure Mechanisms
Two self closing freezer drawer cam and lever
mechanisms automatically pull the drawer shut
when it's within 1 inch of the closed position. The
closure mechanisms are located on the lower corner
areas of the drawer and cabinet.
Each closure mechanism consists of a lever, spring,
and cam. The lever is attached with a spring to a
hook in the base channel. The cam is mounted to
the bottom of the drawer with two T-20 Torx screws.
The lever interacts with the cam to complete the
closing of the drawer.
A pair of pliers can be used to remove the spring
from the hook. The spring and lever can then be
pulled out through the hole in the base channel.
EMI Filter
The EMI Filter is accessed from the back of the
refrigerator and is located on the left side of the
compressor.
To remove the EMI fi lter:
Remove the
1.
5
/
16
-in. hex-head screw that
attaches the bracket to the cabinet.
Pull the bracket out and remove the
2.
1
/
2
-in. nut.
Cut the 2 plastic wire ties that hold the EMI
fi
lter
3.
to the bracket.
Mark and disconnect the wires from the EMI
4.
fi
lter.
5/16-in. Screw
1/2-in. Nut
Wire Tie