– 47 –
Remove the two ¼-in. hex-head screws that
5.
hold the sensor to the rear wall of the oven
cavity.
Oven Temperature Sensor
The oven temperature sensor has an approximate
resistance value of:
1100
•
Ω
at room temperature
1650
•
Ω
at 350°F (177°C)
2650
•
Ω
at clean temperature
The resistance of the sensor can be checked at the
ERC. Place the control panel in the service position.
(See
Touch Panel and ERC
.)
PGS908 - Disconnect wire harness from location J1.
On the wire harness connector, test between pin
location 5 and pin location 7.
PGS968 and PGS975 - Disconnect wire harness from
location CN2. On the wire harness connector, test
between pin location 6 and pin location 8
To remove the temperature sensor:
Remove the oven door. (See
1.
Oven Door Removal
.)
Remove the range from the installation.
2.
Remove the rear cover. (See
3.
Rear Cover Removal
.)
Disconnect the sensor wire harness. Note the
4.
location of the sensor wiring entry hole.
Entry Hole
Sensor Wire Harness
(
Continued next page
)
Gently pull the sensor wire harness into the
6.
oven.
Note:
When reinstalling the sensor, use a small
fl
at-
1.
blade screwdriver to push and guide the sensor
wire harness into the oven liner.
Ensure displaced insulation around the wiring
2.
entry hole is returned to it's original position.
Oven Control Valve
The oven control valve bake and broil windings each
have an approximate resistance value of 1
Ω.
Each
winding is wired in series with an igniter.
The continuity of each valve winding can be
checked on the ERC. Place the control panel in the
service position. (See
Touch Panel and ERC
.)
Bake Winding:
PGS908 - Test between the BA and N.
PGS968 and PGS975 - Test between the yellow wire
on relay RY12 and N.
Check for the approximate resistance value of
106
Ω
. An open measurement indicates an open
valve winding, bake igniter, or open wiring.
Broil Winding:
PGS908 - Test between the BR and N.
PGS968 and PGS975 - Test between the violet wire
on relay RY11 and N.
Check for the approximate resistance value of
176
Ω
. An open measurement indicates an open
valve winding, broil igniter, or open wiring.