background image

PS920SF 

GE Profile

™ 

Series 30" Slide-In Electric Convection Range with Warming Drawer

For answers to your Monogram

®

 or GE

®

  

appliance questions, visit our website at  

geappliances.com or call GE Answer Center

®

 

service, 800.626.2000.

Specification Created 5/13

220459

Dimensions and Installation Information (in inches) 

Receptacle Locations:

 Locally approved flexible service cord or conduit must be used because 

terminals are not accessible after range installation. See shaded area in drawing for location of 

electrical outlet box. Recommended outlet locations allow range to be installed directly against rear 

wall. 

Note:

 This appliance has been approved for 0” spacing to adjacent surfaces above the cooktop. 

However, a 6” minimum spacing to surfaces less than 15” above the cooktop and adjacent 

cabinet is recommended to reduce exposure to steam, grease splatter and heat.

Installation Information:

 Before installing, consult installation instructions for  current 

dimensional data and additional requirements.

MINIMUM DIMENSIONS BETWEEN COOKTOP, WALLS AND ABOVE THE COOKTOP:

A.  Make sure the wall covering, countertop, flooring and cabinets around the range can withstand the heat (up to 200°F) generated by the 
range.
 
B.  Allow 30" minimum clearance between surface units and bottom of unprotected wood or metal cabinet, or allow a 24" minimum when 
bottom of wood or metal cabinet is protected by no less than 1/4" thick flame retardant millboard covered with not less than No 28 MSG 
sheet metal, (.015"), .015" thick stainless steel, .024" aluminum or .020” copper. Acceptable electrical outlet area. Orient electrical receptacle 
so the length is parallel to floor.

C. This appliance has been approved for 0" spacing to adjacent surfaces above the cooktop. However, a 6" minimum spacing to surfaces 
less than 15" above the cooktop and adjacent cabinet is recommended to reduce exposure to steam, grease splatter and heat.

To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage space above the cooktop should be avoided. If 
cabinet storage space is to be provided above the cooktop, the risk can be reduced by installing a range hood that projects at least 5" 
beyond the front of the cabinets.

29

7

8

36”

37

1

4

25

7

8

29

7

8

31

1

4

48

*Depth including door handle is approximately 28-7/8".

*28

7

8

1

4

PHS920SF/PS920SF

A

NOTE C

B

A

C

Both 

Sides

NOTE: 

Use a 4' power cord to prevent interference

with unit when installing.

MINIMUM DIMENSIONS BETWEEN COOKTOP, WALLS AND ABOVE THE COOKTOP:

A.  Make sure the wall covering, countertop, flooring and cabinets around the range can withstand the heat (up to 200°F) generated by the 
range.
 
B.  Allow 30" minimum clearance between surface units and bottom of unprotected wood or metal cabinet, or allow a 24" minimum when 
bottom of wood or metal cabinet is protected by no less than 1/4" thick flame retardant millboard covered with not less than No 28 MSG 
sheet metal, (.015"), .015" thick stainless steel, .024" aluminum or .020” copper. Acceptable electrical outlet area. Orient electrical receptacle 
so the length is parallel to floor.

C. This appliance has been approved for 0" spacing to adjacent surfaces above the cooktop. However, a 6" minimum spacing to surfaces 
less than 15" above the cooktop and adjacent cabinet is recommended to reduce exposure to steam, grease splatter and heat.

To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage space above the cooktop should be avoided. If 
cabinet storage space is to be provided above the cooktop, the risk can be reduced by installing a range hood that projects at least 5" 
beyond the front of the cabinets.

29

7

8

36”

37

1

4

25

7

8

29

7

8

31

1

4

48

*Depth including door handle is approximately 28-7/8".

*28

7

8

1

4

PHS920SF/PS920SF

A

NOTE C

B

A

C

Both 

Sides

NOTE: 

Use a 4' power cord to prevent interference

with unit when installing.

Listed by 

Underwriters 

Laboratories

All GE ranges are equipped with 

an Anti-Tip device. The installation 

of this device is an important, 

required step in the installation  

of the range.

* ADA qualified based 

on Uniform Federal 

Accessibility Standards

*

KW Rating

240V

13.5

208V

10.1

Breaker Size

240V

40 Amps

208V

40 Amps

 Note:

 Check local codes for required breaker size. 

*

Depth including door handle is approximately 28-7/8". 

Reviews: