background image

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

Specification Created 1/08

210378

PSB42YSX 

GE Profile

 42" Built-In Stainless Side-By-Side Refrigerator  

with Dispenser

Total volume and shelf 

area are calculated by 

the Association of Home 

Appliance Manufacturers’ 

standards.

Listed by 

Underwriters 

Laboratories

As an EnErgy STAr

®

 

partner, gE has determined 

that this product meets the 

EnErgy STAr guidelines 

for energy efficiency.

Side Panels

Side panels (not  
supplied) must be 
used whenever  
the sides of the 
refrigerator will  
be exposed. 
* Depending on  

installation 
height.

24"

*84"

*3" to 4"

1-1/2"

Flooring

For proper installation, this refrigerator must be placed 
on a level surface of hard material that is at the same 
height as the rest of the flooring. This surface should be 
strong enough to support a fully loaded refrigerator, or 
approximately 1500 lbs.

NOTE:

 Protect the finish  of the flooring. Cut a large 

section of the cardboard carton and place under the 
refrigerator where you are working.

Grounding the Refrigerator
ImPORTaNT—Please read carefully
FOR PERSONal SaFETy, ThIS aPPlIaNCE muST bE 

PROPERly GROuNDED.

The power supply cord of this appliance is equipped 
with a three-prong (grounding) plug which mates with 
a standard three-prong (grounding) wall receptacle to 
minimize the possibility of electric shock hazard from 
this appliance.

Have the wall outlet and circuit checked by a qualified  
electrician to make sure the outlet is properly grounded.

Where a standard 2-prong wall outlet is encountered, it 
is your personal responsibility and obligation to have it 
replaced with a properly grounded 3-prong wall outlet.

DO NOT, uNDER aNy  

CIRCumSTaNCES, CuT  

OR REmOvE ThE ThIRD  

(GROuND) PRONG FROm  

ThE POWER CORD.
DO NOT uSE aN aDaPTER PluG  

TO CONNECT ThE REFRIGERaTOR  

TO a 2-PRONG OuTlET.
DO NOT uSE aN ExTENSION CORD  

WITh ThIS aPPlIaNCE.

*Finished Width

Electrical

Area

84 1/2" max

83 1/2" min

Finished

Opening

74"

From Floor

to Bottom

of Electrical

24"

5"

5"

3 1/2"

Water Supply

3 1/2"

3"

7"

7"

*The finished cutout width must be: 41-1/2" for 42" models

Water and Electrical locations

The opening must  be prepared with the electrical and 
water supply located as shown.

The cutout depth must be 24"

The refrigerator will project forward, slightly beyond 
adjacent cabinets, depending on your installation.

additional Specifications

•  A 120 volt, 60Hz, 15 or 20 amp power supply is required.  

An individual properly grounded branch circuit or circuit 
breaker is recommended. Install a properly grounded 3-
prong electrical receptacle recessed into the back wall. 
Electrical must be located on rear wall as shown.

Note:

 GFI (ground fault interrupter) is not recommended.

•  Water line can enter the opening through the floor or 

rear wall. The water line installed should be 1/4" O.D. 
copper tubing or GE SmartConnect

 tubing between 

the cold water line and water connection location. The 
line should be long enough to extend to the front of the 
refrigerator. Installation of an easily accessible shutoff 
valve in the water line is required.

The Installation Space