background image

Dimensions and Installation Information (in inches) 

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

Listed by 

Underwriters 

Laboratories

Under Oven Installation 

Warming Drawer Dimensions 

Undercounter Installation 

Specification Created 1/07

221128

Optional Accessories: 

JXPN2 – Optional Pan Set 
Accessory for Warming 
Drawer. Two commercial 
pans with lids (4” deep) 

ZXD30B –3/4” panel kit 
capability 

Undercounter Installation: A solid barrier must 
be installed at least 1” from the lowest point of the 
bottom of cooktop burner box to the top of the 
cutout. Use any solid material such as 1/4”-thick 
plywood. Allow at least 1/4” air gap between the 
barrier and the top of the warming drawer. See 
label on top of the warming drawer for approved 
cooktop models. 
Under Oven Installation: Additional clearance 
between cutouts may be required. Check to be 
sure that oven supports above the warming  
drawer location do not obstruct the required  
interior 23-1/2” depth and 9-1/4” height. 
Door handle protrudes 2-3/4” from door face. 

Cabinets and drawers on adjacent 45° and 90° 

walls should be placed to avoid interference with 

the handle.
Installation Information:
 Before installing, consult 
installation instructions packed with product for 
 current dimensional data.

KW Rating

120V

.45

Breaker Size

120V

15 Amps

25

1-1/2"  

Cabinet top

36"

Countertop

height

Electrical outlet  

42" max. from  

right side

Electrical outlet  

flush with side of  

cabinet 7" max.

Install 2x4 or 2x2  

anti-tip block against  

rear cabinet wall 9" from  

floor to bottom of block 

 

 

 

 

 

1" Min.*

9-1/4

28-1/2

Install a solid barrier  

below a cooktop  

(see note).

9

7

23-1/2 min.

Electrical

outlet 16" max.

from left side

Install a solid barrier  

and a 1/4" min. air gap  

above warming drawer.

Solid barrier

1/4" Air gap

298Dia1

9-1/4

Locate

electrical

outlet in

adjacent

cabinet

16" from

left side

or 42"

from right

side.

10-1/2

24" 

recommended

from floor 

for under 

countertop

installation

23-1/4

23-1/2" Min.

Inside

30

28-1/2

9

Allow 5/8"  

overlap on  

all sides

23-1/4

23-1/2"  

min.

1" Min. above toekick 

or adjust to oven 

installation height

2" min. 

A

Oven  

cutout

B

9-1/4

9

Allow 5/8" overlap 

on all sides

23-1/4

23-1/2"  

min.

1" Min. above toekick 

2" min. 

2x2 or 2x4  

anti-tip block  

against rear 

wall 9" from  

floor to bottom  

of block

2x2 or 2x4  

anti-tip block  

against rear 

wall 9" from  

floor to bottom  

of block

Oven  

cutout

9-1/4

10-1/2

30

28-1/2

10-1/2

PTD915BM/CM/WM 

GE Profile

 30" Warming Drawer

 

2x4 or 2x2

runners or solid

bottom

Install

2x4 or 2x2

Anti-Tip

Block 9" 

From Floor 

to Bottom

of Block

353Dia4

9

Reviews: