background image

3

DEH40206 Installation Instructions

The 1-, 2- and 4-button dataline switches mount in standard
single-gang switch boxes. The 8-button unit mounts in a
standard 2-gang box. The dataline is typically connected in a
“daisy-chain” from switch to switch, eliminating expensive
home runs. To assure proper operation, 

you must have a

good dataline

 which:

1. Provides 24 VAC power to each switch
2. Has a low resistance connection of the red and black wires

between all switches and the relay panel

3. Has no short of the red and/or black to ground

24 VAC Power

The power supply in the relay panel must be on.

 To test

for 24 VAC power at each switch, press the softwire tab after
you have connected the dataline but before mounting the
switch in the electrical box. The red LEDs for each button
should flash.

DATALINE SWITCH INSTALLATION AND TESTING

Low-Resistance Red/Black Data Path

After wiring the last switch on the local dataline, disconnect
the red and black wires from the Local Dataline terminals in
the relay panel and wire nut them together. Then measure the
resistance between the red and black terminals on the last
switch. It should be less than 3 ohms. If it is higher, work
backwards toward the relay panel, checking the resistance at
each switch to find the bad connection. When finished,
reconnect the Local Dataline at the panel.

Shorted Dataline

After the dataline resistance test checks out, you can easily
test for a shorted dataline by measuring the resistance from
red to white, then black to white anywhere on the dataline.
You should see an open circuit. If there is a short, start at the
last switch and work backwards as above to locate it.

Self Installation and Unconfiguring

When the switch is first connected to a panel it is automati-
cally issued a network address—it is configured. If you are
moving a switch to another network you must first
unconfigure it to delete its network address. (A configured
switch could have the same address as a node on another
network.)

To unconfigure a switch, first make sure that the fourth DIP
switch is in the ON position. Leave the power line on but
disconnect the dataline. (Disconnecting the dataline prevents
the panel from configuring the switch again.) Hold down the
softwire tab for at least 10 seconds. At 10 seconds the locator
LED will turn off indicating that the switch is unconfigured.

Summary of Contents for ProSys DEH40206

Page 1: ... period Dip switch 4 must be in the off position to enable this feature as shown on page 8 Order this feature by adding a K to the part number for the 1 2 4 and 8 button switch For example RS2PSxK Any button on a Softwire Switch may be softwired to Any relay or group of relays within a single relay panel A channel within a single relay panel The same channel among multiple panels requires an RCLK8...

Page 2: ...nch twist lay on pairs 6 inch twist lay on cable Plenum rated copolymer jacket 0 230 O D FEP 0 010 insulation 0 060 O D 30 pF foot maximum capacitance 20 C to 150 C operating temperature range 17 lbs per 500 foot reel UL rated If you have purchased the ProSys Lighting Control System the stand alone system the devices panels switches and clock will be in self install mode This means that as soon as...

Page 3: ...tween the red and black terminals on the last switch It should be less than 3 ohms If it is higher work backwards toward the relay panel checking the resistance at each switch to find the bad connection When finished reconnect the Local Dataline at the panel Shorted Dataline After the dataline resistance test checks out you can easily test for a shorted dataline by measuring the resistance from re...

Page 4: ... single panel see next page for softwiring a dataline switch For example assume that you want the top two buttons of a 4 button switch to control open office areas associated with relays in Panel 01 while the third button controls common areas rest rooms and hallways in Panel 02 The form below shows how to record this intent and also shows the labeling for each switch button Finally write the swit...

Page 5: ...t it provides a simple way of manually overriding all of the relays which are grouped to an automation channel A H within a panel With the wallplate removed and the switch s master button flipped open 1 Press the SOFTWIRE tab The LED next to the tab will turn on then the individual button LEDs will start flashing 2 Press the switch button you want to softwire Master Button on an RS1PS x The LED fo...

Page 6: ...t Lift the button out twisting it slightly if necessary to free the small hook holding the center edge of the button in place To replace the button position the small center hook in place and press the hinge pin into the hinge bracket until it snaps in place Remove Replace Screwless Wallplate To remove the screwless cover plate press in the black tab at the bottom edge of the plate and lift the pl...

Page 7: ...Figure 7 shows how the four buttons on a quad switch would be softwired to create this switching function All of the buttons are wired as Patterns Reviewing the LED operation shows why this is important see Figure 6 When the occupant toggles the top button ON relay 01 01 will turn ON and relay 01 02 will turn OFF to give 1 3 lighting The LED for 1 3 will turn on red Pressing the second button caus...

Page 8: ...here Pressing the Master Button again would restore the lighting in the two zones which had been on without having to turn on the entire floor You can change the operating scenario of the Master Button using the first two DIP switches located on the back of the switch The DIP switches are normally covered by a label to prevent accidental changes As shown above the factory default setting is all DI...

Page 9: ... button 1 controlling a Pattern in which the north half of the floor is ON and south half is OFF The second button does just the reverse With this combination whenever the cleaners turn on one half of the floor the other half turns off automatically saving half the lighting Furthermore since switch 01 01 has been configured as a cleaning switch the cleaning crew cannot accidentally put an occupant...

Page 10: ......

Reviews: