background image

6

DEH40206 Installation Instructions

SWITCH BUTTON LABELING

The individual switch buttons provide space for 

3

8

" wide x 1

1

16

"

long (9mm x 30mm) label directories. The directory labels can
be attached simply by removing the clear lenses, positioning
the labels and replacing the lenses as shown at right.

If desired, the buttons may be completely removed from the
base plate and labeled separately. You may find this method
easier to achieve better alignment of the labels.

To remove a button from a 1-, 2- or 4-button switch, open it
out from the base until it is at a 90° angle, then gently rotate
it up or down until it snaps free of the hinge bracket. To
replace the button, press the hinge pin into the hinge bracket
until it snaps in place, then close the button into position.

Removing buttons from an 8-button switch is slightly
different. With your fingernail or small screwdriver, pry the
hinge end of the button free from the hinge bracket. Lift the
button out, twisting it slightly, if necessary, to free the small
hook holding the center edge of the button in place. To replace
the button, position the small center hook in place and press
the hinge pin into the hinge bracket until it snaps in place.

Remove/Replace Screwless Wallplate

To remove the screwless cover plate, press in the black tab at
the bottom edge of the plate and lift the plate up and off. To
replace the cover plate, place the hang bar at the top of the
plate onto the hang hook at the top of the switch base and
snap the bottom in place until it clicks as shown in 

Figure 4

.

Record Switch Reference Numbers

The switch’s reference number (Panel #-Switch #) should be
written on the small label placed in the lower right hand
corner of the switch base, so that it is visible when the cover
is removed.

The relays or channel associated with each button of the switch
are recorded on the 

DATALINE SWITCH DOCUMENTA-

TION

 form supplied with the relay panel. The completed form

should be stored in the cover of the relay panel that is
connected to this local dataline.

Panel#

Switch#

01
02

Figure 4 – Dataline Switch Numbering

Summary of Contents for ProSys DEH40206

Page 1: ... period Dip switch 4 must be in the off position to enable this feature as shown on page 8 Order this feature by adding a K to the part number for the 1 2 4 and 8 button switch For example RS2PSxK Any button on a Softwire Switch may be softwired to Any relay or group of relays within a single relay panel A channel within a single relay panel The same channel among multiple panels requires an RCLK8...

Page 2: ...nch twist lay on pairs 6 inch twist lay on cable Plenum rated copolymer jacket 0 230 O D FEP 0 010 insulation 0 060 O D 30 pF foot maximum capacitance 20 C to 150 C operating temperature range 17 lbs per 500 foot reel UL rated If you have purchased the ProSys Lighting Control System the stand alone system the devices panels switches and clock will be in self install mode This means that as soon as...

Page 3: ...tween the red and black terminals on the last switch It should be less than 3 ohms If it is higher work backwards toward the relay panel checking the resistance at each switch to find the bad connection When finished reconnect the Local Dataline at the panel Shorted Dataline After the dataline resistance test checks out you can easily test for a shorted dataline by measuring the resistance from re...

Page 4: ... single panel see next page for softwiring a dataline switch For example assume that you want the top two buttons of a 4 button switch to control open office areas associated with relays in Panel 01 while the third button controls common areas rest rooms and hallways in Panel 02 The form below shows how to record this intent and also shows the labeling for each switch button Finally write the swit...

Page 5: ...t it provides a simple way of manually overriding all of the relays which are grouped to an automation channel A H within a panel With the wallplate removed and the switch s master button flipped open 1 Press the SOFTWIRE tab The LED next to the tab will turn on then the individual button LEDs will start flashing 2 Press the switch button you want to softwire Master Button on an RS1PS x The LED fo...

Page 6: ...t Lift the button out twisting it slightly if necessary to free the small hook holding the center edge of the button in place To replace the button position the small center hook in place and press the hinge pin into the hinge bracket until it snaps in place Remove Replace Screwless Wallplate To remove the screwless cover plate press in the black tab at the bottom edge of the plate and lift the pl...

Page 7: ...Figure 7 shows how the four buttons on a quad switch would be softwired to create this switching function All of the buttons are wired as Patterns Reviewing the LED operation shows why this is important see Figure 6 When the occupant toggles the top button ON relay 01 01 will turn ON and relay 01 02 will turn OFF to give 1 3 lighting The LED for 1 3 will turn on red Pressing the second button caus...

Page 8: ...here Pressing the Master Button again would restore the lighting in the two zones which had been on without having to turn on the entire floor You can change the operating scenario of the Master Button using the first two DIP switches located on the back of the switch The DIP switches are normally covered by a label to prevent accidental changes As shown above the factory default setting is all DI...

Page 9: ... button 1 controlling a Pattern in which the north half of the floor is ON and south half is OFF The second button does just the reverse With this combination whenever the cleaners turn on one half of the floor the other half turns off automatically saving half the lighting Furthermore since switch 01 01 has been configured as a cleaning switch the cleaning crew cannot accidentally put an occupant...

Page 10: ......

Reviews: