background image

GFK-2893K 

QuickPanel

Quick Start Guide 

5

 

Status 

Indicator LED

Touchscreen 

LCD

SD Card

USB 
Host 

Ports

MICRO 

USB

LAN2

COM1

LAN1

Input 

Power

LINE 

OUT

COM2

IC755CxS10CDx Profile and Hardware Features 

Note: 

Refer to the table

 

IC755CxS10CDx 

Specifications

 for drawing dimensions.

 

Summary of Contents for QuickPanel+ IC755CxS06RDx

Page 1: ...ls Operator Interface Products QuickPanel Operator Interface IC755CxS06RDx 6 Display IC755CxW07CDx 7 Display IC755CxS10CDx 10 Display IC755CxS12CDx 12 Display IC755CxS15CDx 15 Display Quick StartGuide...

Page 2: ...f not strictly observed could result in personal injury or death Caution Indicates a procedure condition or statement that if not strictly observed could result in damage to or destruction of equipmen...

Page 3: ...T MIC IN Input Power LAN USB Host Ports Serial Interface LCD Active Area 115 2 x 86 4 mm 4 5 x 3 4 in 115 2 mm 4 5 in 192 mm 7 56 in x 2 36 mm 1 42 in x 2 137 mm 5 39 in x 2 183 50 mm 7 22 in 75 mm 2...

Page 4: ...Battery Cover COM USB Host Ports LAN Input Power SD Card MICRO USB LINE OUT MIC IN Status Indicator LED Touchscreen LCD IC755CxW07CDx Profile and Hardware Features Note Refer to the table IC755CxW07C...

Page 5: ...de 5 Status Indicator LED Touchscreen LCD SD Card USB Host Ports MICRO USB LAN2 COM1 LAN1 Input Power LINE OUT COM2 IC755CxS10CDx Profile and Hardware Features Note Refer to the table IC755CxS10CDx Sp...

Page 6: ...6 QuickPanel Quick Start Guide GFK 2893K IC755CxS12CDx Profile and Hardware Features Note Refer to the table IC755CxS12CDx Specifications for drawing dimensions...

Page 7: ...de 7 Touchscreen LCD Status Indicator LED SD Card Input Power LINE OUT USB Host Ports MICRO USB COM2 LAN2 COM1 LAN1 IC755CxS15CDx Profile and Hardware Features Note Refer to the table IC755CxS15CDx Sp...

Page 8: ...lti touch Single touch Communications Ethernet Port 1x10 Base T 100 Base TX Serial Port 1x RS 232C COM1 5 pin connector USB Host 2x USB 2 0 Type A Maximum power 5 V at 0 5 A USB Device 1x USB 2 0 mini...

Page 9: ...ns Ethernet Port 1x 10 100Base T RJ 45 Serial Port 1x RS 232 UART port 5 pin connector USB Host 2x USB 2 0 Type A Maximum power 5 V at 0 5 A USB Device 1x USB 2 0 mini Type B Storage 1x SD SDHC card s...

Page 10: ...ns Ethernet Port 2x 10 100Base T RJ 45 Serial Port 1x RS 232 UART port 1x RS 232 485 port 2x 5 pin connector USB Host 2x USB 2 0 Type A Maximum power 5 V at 0 5 A USB Device 1x USB 2 0 mini Type B Sto...

Page 11: ...5 1x 10 100Base T RJ 45 for IC755CxS12CDA Serial Port 1x RS 232 UART port 1x RS 232 485 port 2x 5 pin connector 1x 10 pin connector for IC755CxS12CDA USB Host 2x USB 2 0 Type A Maximum power 5 V at 0...

Page 12: ...Ethernet Port 2x 10 100Base T RJ 45 Serial Port 1x RS 232 UART port 1x RS 232 485 port 2x 5 pin connector USB Host 2x USB 2 0 Type A Maximum power 5 V at 0 5 A USB Device 1x USB 2 0 mini Type B Stora...

Page 13: ...or less Environment Pollution Degree 2 Indoor use only Vibration Resistance 5 to 9 Hz single amplitude 3 5 mm 9 to 150 Hz constant accelerated velocity 9 8 m s2 X Y Z directions 10 time 100 minutes C...

Page 14: ...cations in the table General Specifications The mating power terminal block supports stranded 30 to 14 AWG 0 05 to 2 00 mm 2 wires The user calculates proper gauge wiring for current carrying capacity...

Page 15: ...eplacing the battery Refer to the section Mounting on a VESA arm 3 The battery should only be installed when the unit is powered off 4 Care should be taken to protect and insert the battery with corre...

Page 16: ...harness connector to the header noting keyed orientation IC755CxS06RDx Battery Harness Connection 3 Verify that positive red is down and negative black is up 4 Wrap the harness connector around to ma...

Page 17: ...ire Warning Use of batteries not specified for use with the QuickPanel product may present a risk of fire or explosion Caution Replace the battery for the IC755CxS06RDx only with GE battery part numbe...

Page 18: ...0 3 Nm 2 26 in lb 5 Apply dc power to the unit During normal startup and operation the QuickPanel status LED indicator displays as follows Solid amber while the QuickPanel unit is starting up Solid gr...

Page 19: ...C755CxSxxCDx units LED State QuickPanel State Amber solid Operating system starting Green solid Normal operating state Green blinking Backlight off Red blinking Backlight failure Off Power not applied...

Page 20: ...he protective film from the QuickPanel display screen 2 Wipe the display unit of any dust or fingerprints 3 Peel back a corner of the clear side of the protective sheet 4 Begin applying the corner to...

Page 21: ...room to insert and remove the SD card cables and mounting brackets Select a location that allows natural convection air flow from bottom to top of the QuickPanel enclosure Do not mount the QuickPanel...

Page 22: ...enclosure you will need the following equipment One 2 Phillips head screwdriver Mounting brackets supplied The mounting holes for the IC755CxS06RDx IC755CxW07CDx and IC755CxS10CDx are located on the...

Page 23: ...anel Quick Start Guide 23 IC755CxS10CDx Mounting Holes The IC755CxS12CDx and IC755CxS15CDx mounting holes are located on the top bottom and sides of the unit IC755CxS12CDx Mounting Holes IC755CxS15CDx...

Page 24: ...unit To install the QuickPanel 1 Cut an opening in the panel according to the specifications in the following figures Note Panel cutout tolerances are 0 50 0 00 mm 0 02 0 00 in Panel Thickness 1 0 to...

Page 25: ...to 5 0 mm 0 06 to 0 20 in 228 mm 8 98 in 302 mm 11 89 in IC755CxS12CDx Panel Cutout Dimensions Panel Thickness 1 6 to 5 0 mm 0 06 to 0 20 in 379 mm 14 92 in 305 mm 12 01 in IC755CxS15CDx Panel Cutout...

Page 26: ...wing figure 5 Tighten the screws on the mounting bracket in a clock wise direction Torque Range for Mounting Clamp Screws Display Unit Torque Range IC755CxS06RDx 0 3 Nm 2 66 in lb IC755CxW07CDx 0 3 Nm...

Page 27: ...ocated on the back of the unit displayed in the following figures The mounting holes for IC755CxS06RDx and IC755CxW07CDx attach with M4 screws that are 6 mm 0 24 in or less in length The mounting hole...

Page 28: ...IC755CxW07CDx or IC755CxS06RDx VESA Mounting Holes 100 mm 100 mm 100 mm 3 94 in 100 mm 3 94 in IC755CxSxxCDx VESA Mounting Holes Note For user manuals product updates and other information go to the S...

Page 29: ...1 24 V dc 2 GND 3 FG IC755CxSxxCDA supports both 12 V dc or 24 V dc IN 4 6 2 Ethernet Port Details Interface Ethernet 10BASE T 100BASE TX Pin Signal Name Pin out 1 TX 2 TX 3 RX 4 NC 5 NC 6 RX 7 NC 8 N...

Page 30: ...tart Guide GFK 2893K 4 6 4 Serial Port Details 4 6 4 1 IC755CxS06RDx 4 6 4 1 1 Serial Port COM1 Interface RS 232 Pin Signal Name 1 TXD 2 RXD 3 RTS 4 CTS 5 SGND Pin 1 Pin 5 1 2 3 4 5 IC755CxS06RDx Seri...

Page 31: ...GFK 2893K QuickPanel Quick Start Guide 31 4 6 4 2 IC755CxW07CDx Interface x1 RS 232 Pin Signal Name 1 TXD 2 RXD 3 RTS 4 CTS 5 SGND Pin 1 Pin 5 1 2 3 4 5 IC755CxW07CDx Serial Port COM1 Pin out...

Page 32: ...32 QuickPanel Quick Start Guide GFK 2893K 4 6 4 3 IC755CxSxxCDx 4 6 4 3 1 Serial Port COM1 Interface RS 232 Pin Signal Name 1 TXD 2 RXD 3 RTS 4 CTS 5 SGND C755CxSxxCDx Serial Port COM1 Pin out...

Page 33: ...Pin RS 232 RS 485 Signal Name Signal Name Full duplex Signal Name Half duplex 1 TXD TXD DATA 2 RXD TXD DATA 3 RTS RXD DATA 4 CTS RXD DATA 5 SGND SG SG Full duplex RS 485 is backwards compatible to RS...

Page 34: ...A B C D applicable to 7 10 12 15 Display units Class I Division 2 Groups A B C D Class 2 Division 2 Groups F G Class 3 Division 1 and Division 2 applicable only to 6 Display unit Certification by Und...

Page 35: ...ng for Hazardous areas and the ATEX marking for Zone 2 explosive atmospheres Suitable for use in Class I Division 2 Groups A B C D applicable to 7 10 12 15 Display units Suitable for use in Class I Di...

Page 36: ...is set at a level not exceeding 140 of the peak rated voltage value at the supply terminals to the equipment USB retaining clamp must be used in hazardous location installations as follows 1 Connect t...

Page 37: ...ved or the area is known to be non hazardous EXPLOSION HAZARD Substitution of components may impair suitability EXPLOSION HAZARD DO NOT VESA MOUNT Panel mount only with enclosures that shall only be o...

Page 38: ...generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this e...

Page 39: ...allation and operation considerations were taken into account Shielding USB cables Limiting RS 232 cables to 15 m 49 2 ft in length Using Audio ports only during operational maintenance Although these...

Page 40: ...Solution Provider solutionprovider ip ge com Technical Support If you have technical problems that cannot be resolved with the information in this manual contact us by telephone or email or on the we...

Page 41: ...n Italian Czech Spanish Asia Pacific Online Technical Support http support ge ip com Phone 86 400 820 8208 86 21 3217 4826 India Indonesia and Pakistan Technical Support Email Support cn ip ge com Chi...