CONFIGURATION MODE
The configuration mode is used to set the RAK148H2 to
match the heating/cooling system. This thermostat function
with up to 2-stage heat pump systems.
To configure the RAK148H2, perform the following steps:
Note:
Operation being set will blink in the display.
1.
Slide the
Function
switch to the
OFF
position.
2.
Remove the thermostat’s front cover.
3.
To enter the configuration mode, simultaneously hold
the
LEFT
and
RIGHT
buttons in for 3 seconds while the
thermostat is in
OFF
mode. (See diagram on page 3.)
4.
Once in the configuration mode, press the
<
or
>
button to change settings within each screen.
-
Press the
RIGHT
button to advance to the next screen.
- Press the
LEFT
button to return to the previous screen.
NOTE:
To exit configuration mode at any time, slide the
Function
switch to
Heat
or
Cool
.
Configuration Mode Settings
The setup screens for Configuration Mode are as follows:
1.
Temperature Scale (°F or °C)—
Choose
Fahrenheit or Celsius.
Press the
<
or
>
button to select.
Press the
RIGHT
button to advance to the next screen.
NOTE:
Default factory setting is Fahrenheit
.
2.
Heat System—
Check model number on the Hotpoint
chassis to determine the primary heating method.
AZ11H*****
is a heat pump and is the thermostat factory setting.
AZ11E*****
is a straight electric heat model and requires a mode
setting change.
To change the heating mode configuration, press the
RIGHT
button to advance to the
HSH
screen. Press the
<
or
>
button to select
HSE
.
Press the
RIGHT
button to advance to the next screen.
3.
Temperature Differential—Stage 1—
(1–9°F) (1–5°C)
Set the number of degrees between the
“setpoint” temperature and the
“turn on” temperature for first stage.
10