31-5000842 Rev. 0
11
INSTALLER MENU (cont)
INSTALLATION INSTRUCTIONS
Menu Item
(Mode advances
to next, Fan
returns to
previous)
Description
Default
Setting
Range/
Selections
(+ or - to
change)
8 Wire
Setting
Availability
2- Way
Setting
Availability
01
Units
(F=Fahrenheit or C=
Celsius)
F
F, C
X
02
Set Current Hours (military
time)
Only used if Scheduling Energy
Savings (setting 20)
0
0 to 23
X
X
03
Set Current Minutes
Only used if Scheduling Energy
Savings (setting 20)
0
0 to 59
X
X
06
Fan Mode
A = Auto, only allows auto
(cyclic) fan selection in heating/
cooling modes
C = Continuous, allows
selection of continuous or
auto (cyclic) in heating/cooling
modes
C
A, C
X
07
Heat Pump
Is the unit a heat pump? Y=
Yes, n= No
Y
Y, n
X
08
Reversing Valve Type
b
b, O
X
09
Number of Compressor
Stages
2
1, 2
X
10
Heating Differential 1
Number of degrees (F) from set
point required to activate 1st
stage heat
1
1 to 10
X
11
Cooling Differential 1
Number of degrees (F) from set
point required to activate 1st
stage cool
1
1 to 10
X
12
Heating Differential 2
Number of degrees (F) from 1st
stage heat required to activate
2nd stage heat
1
1 to 10
X
13
Cooling Differential 2
Number of degrees (F) from 1st
stage cool required to activate
2nd stage cool
1
1 to 10
X
14
Heating Differential 3
Number of degrees (F) from 2nd
stage heat required to activate
3rd stage heat
1
1 to 10
X
15
Auto Changeover
Y = enables autochangeover
option under "Mode"
n
n, Y
X
Summary of Contents for RAK190V