STEP 3 (continued)

5. Remove and save the three screws holding the 

front of the air discharge screen in place. Align 

the metal seal strip in place as shown and secure 

with the three screws. Center the strip and snug 

the screws. 

6. Remove the seven screws that hold the louver 

section in place and remove it.

7. Reconnect power and check operation.
8. Reinstall the room cabinet front by hooking the 

top over the rail along the chassis top. Push it in 

at the bottom.

9. Slide the transition duct into place under the 

adapter and secure it with the two thumb screws.

STEP 4

 

Removal of the chassis from the case

 

for service

NOTE:

 If it becomes necessary to remove the 

chassis from the case, the following procedure 

should be performed.
1. Remove the two thumb screws securing the 

transition duct to the bottom of the lateral duct 

adapter.

2. Carefully slide the transition duct forward to 

remove it from the chassis.

3. Remove the room cabinet front.
4. Remove the chassis from the case for service.