Introduction

These instructions describe the installation of a Pro-Stock  
Spectra RMS G frame single- and three-phase main circuit 
breaker kit into a ReliaGear lighting panelboard. These kits are 
not for use in standard, factory-assembled panelboards.

The catalog numbers for the single-phase kits are MB332

MB332WB

, MB335WB and MB336WB 

(circuit breaker included) and 

the lists of parts are found in Tables 1 and 2. The catalog numbers 
for the three-phase kits are MB333

MB333WB

, MB331WB and 

MB334WB 

(circuit breaker included) and the lists of parts are 

found in Tables 3 and 4.

Table 1. Parts list for the 240 and 480 Vac Spectra RMS  
G frame single-phase circuit breaker installation kit, catalog 
number MB332.

Item #

Description

Part #

Qty.

1

Shield insert, 240 Vac

100811 32P26

1

Shield insert, 480 Vac

100811 32P25

1

1

Shield insert, 240 Vac, 
ReliaGear

100811 32P31

1

Shield insert, 480 Vac, 
ReliaGear

100811 32 P32

1

2

Nut, 5/16-1 8

N269P23B6

2

3

Screw, #10-32 x 3/8

N722 EP16006B6

6

4

Screw, #10-32 x 3 -3/4

N37P 16060B6

2

5

Lock washer

N405P40B6

2

6

Flat washer

41 52

2

7

Cap screw, 1 /2-1 3 x 7/8

N17 0P2901 4B6

2

8

Washer, belleville, 1 /2

75A105503P103

2

10

Connection strap

10 083059P2

4

12

B-Phase Barrier

569B701G1

1

1 5

Label, “MAIN”

31 5A7337P 1

1

16

1 39C5473P63

1

Introduction

Ces instructions décrivent l’installation d’un kit de disjoncteur 
principal Spectra RMS G frame à phase simple et trois phases 
dans un panneau d’éclairage ReliaGear. Ces kits ne doivent pas 
être utilisés sur des panneaux standards fabriqués en usine.

Les numéros de catalogue pour les kits à phase simple sont 

MB332, MB332WB, MB335WB et MB336WB 

 (disjoncteur inclus) et 

les listes des pièces se trouvent aux Tables 1 et 2. Les numéros de 
catalogue pour les kits à trois phases sont 

MB333, MB333WB, 

MB331WB et MB334WB 

 (disjoncteur inclus) et les listes des pièces 

se trouvent aux Tables 3 et 4.

Table 1. Liste des pièces pour kit d’installation de disjoncteur 
Spectra RMS G frame à phase simple, 240 et 480 Vca, numéro de 
catalogue MB332.

Item #

Description

Pièce #

Qté.

1

Rajout du garde, 240 Vca

100811 32P26

1

Rajout du garde, 480 Vca

100811 32P25

1

1

Rajout du garde, 240 Vac, 
ReliaGear

100811 32P31

1

Rajout du garde, 480 Vac, 
ReliaGear

100811 32 P32

1

2

Écrou, 5/16-1 8

N269P23B6

2

3

Vis, #10-32 x 3/8

N722 EP16006B6

6

4

Vis, #10-32 x 3 -3/4

N37P 16060B6

2

5

Rondelle de retenue

N405P40B6

2

6

Rondelle plate

41 52

2

7

Vis ‡ chapeau, 1 /2-1 3 x 7/8

N17 0P2901 4B6

2

8

Rondelle, belleville, 1 /2

75A105503P103

2

10

Courroie de connexion

10 083059P2

4

12

Barrière de phase B

569B701G1

1

1 5

Étiquette “MAIN”

31 5A7337P 1

1

16

1 39C5473P63

1

1

7

Mounting bracket

 

1

10086929P11

1

1

7

1

1

10086929P11

12

B-Phase Barrier

569B701G1

12

Barrière de phase B

1

569B701G1

B-Phase Barrier

Insulator SG600A

Mounting bracket

 

Isolateur SG600A

Summary of Contents for ReliaGear 400 A

Page 1: ... 1 2 75A105503P103 2 10 Connection strap 10 083059P2 4 12 B Phase Barrier 569B701G1 1 15 Label MAIN 315A7337P1 1 16 139C5473P63 1 Introduction Ces instructions décrivent l installation d un kit de disjoncteur principal Spectra RMS G frame à phase simple et trois phases dans un panneau d éclairage ReliaGear Ces kits ne doivent pas être utilisés sur des panneaux standards fabriqués en usine Les numé...

Page 2: ...929P11 1 Table 2 Liste des pièces pour kit d installation de disjoncteur à phase simple Spectra RMS G frame 240 et 480 Vca avec disjoncteur inclus numéro de catalogue MB332WB MB335WB et MB336WB Item Description Pièce Qté 1 Rajout du garde 240 Vca 10081132P26 1 Rajout du garde 480 Vca 10081132P25 1 1 Rajout du garde 240 Vac ReliaGear 10081132P31 1 Rajout du garde 480 Vac ReliaGear 10081132P32 1 2 É...

Page 3: ... l assemblage de l intérieur de son emballage et vérifier que toutes les pièces y sont telles que données sur la liste d emballage 2 Retirer les huit vis fixant le garde à l intérieur du panneau Soulever le garde et le mettre de côté avec les vis 3 Retirer le kit de disjoncteur de son emballage et vérifier que toutes les pièces y sont telles que données sur la liste d emballage Si vous installez u...

Page 4: ... a risque de blessure grave ou de mort La barrière de phase doit être installée avant de mettre le panneau sous tension 6 Placez la barrière de phase 12 autour de la barre omnibus de phase B et elle se placera entre le support de bus et le disjoncteur 7 Pour un panneau avec MB332WB MB333WB MB335WB MB336WB MB331WB or MB334WB Montez 16 sur les rails intérieurs avec des vis de 10 32 x 3 8 3 Resserrer...

Page 5: ...e circuit breaker kit catalog number MB332 MB335WB MB336WB or MB332WB as a main breaker into a new 400 A or 600 A lighting panelboard Figure 1 Installation d un kit de disjoncteur Spectra RMS G frame Pro Stock numéro de catalogue MB332 MB335WB MB336WB or MB332WB comme disjoncteur principal dans un panneau d éclairage nouvelle 400 A ou 600 A ...

Page 6: ...pal dans un panneau d éclairage nouvelle 400 A ou 600 A 1TQC213000Z0011 DEH40190 APR2021 ABB Inc 305 Gregson Drive Cary NC 27511 Copyright 2021 ABB All rights reserved Information provided is subject to change without notice Please verify all details with ABB All values are design or typical values when measured under laboratory conditions and ABB makes no warranty or guarantee express or implied ...

Reviews: