– 3 –
5. Push orifi ce down through burner box and
remove the tube assembly from the range.
6. Use a
1
/
2
-in. wrench to remove the valve from
the gas line.
SPARK MODULE
The spark module is located on the back of the
oven, near the bottom. It is protected by a metal
housing. The spark module is mounted with two
tabs, which snap into corresponding slots. To
remove the module, use a flat blade screwdriver to
bend the tabs toward the module body and release
the tab from the slot.
Spark Module
SPARK ELECTRODES
The range has 2 spark electrodes. They have
different part numbers due to wire length. The wires
are held in a retaining clip below the burner box.
The burner box must be removed to route the wires
correctly when replacing an electrode.
Spark Electrodes
When replacing the spark electrodes, tie a string to
the spark electrode wire as shown. From the top of
the range, pull the spark electrode wire up through
the range. Use the string to pull the new spark
electrode wire back through the range.
Spark Electrode Wire
String
Housing
Summary of Contents for RGA720EK
Page 5: ... 5 Wiring Diagram ...
Page 6: ... 6 Schematic ...