background image

– 2 –

MANIFOLD PANEL

There are 8 screws that hold the manifold panel in 
place. 

4 Screws (Behind the Gas Control Knobs) 

4 Screws (Top and Bottom of the Manifold Panel)

SWITCH REMOVAL

1.  Prop open the  cooktop.

2.  Remove the gas control knobs, then remove the 

manifold panel.

3.  To remove the switch, rotate the switch 15-20 

degrees counterclockwise and pull the switch off 
the manifold.

Note:

 

For switches located behind the bracket, the 
valve must fi rst be removed from the manifold.

All 4 switches come as an assembly.

TOP BURNER VALVE REMOVAL

1.  Remove the switch from the valve. (See 

Switch

 

Removal.

)

2.   For the desired valve, remove the 

1

/

4

-in. hex-

head screw on the manifold.

3.   Lift burners off the orifi ces, then locate the 

orifi ce that corresponds to the desired valve.

4.   Remove the 

3

/

4

-in. hex nut holding the orifi ce 

and tube assembly as shown.

Bracket

Reviews: