background image

3

FLUSH PROCEDURE

Whenever water of unknown quality is passed through 
the GE Water Filtration system, filter elements should be 
discarded and the filtration system flushed. 

Circumstances that may require flushing the system are:

Boil-water advisory.

Flooding of the GE Water Filtration system.

Long-term non-use.

The procedure for flushing the GE Water Filtration system is:

See 

Filter Cartridge Installation or Replacement

section and

follow steps 1, 2, 3 and 4.

Next, reinstall the sump (without the filter element), 
turn water on and flush water through the faucet.

Then, turn water off, remove sump, empty water out of
sump and install new filter element.

Follow steps 5–10 in the 

Filter Cartridge Installation or

Replacement 

section to complete.

4

3

2

1

FILTER CARTRIDGE INSTALLATION OR REPLACEMENT

CAUTION:

Never remove the sumps

when water pressure is in the Water
Filtration system.

Close the water supply/saddle valve 
to the filter. 

Open the filtered water

faucet.

Remove the sump, using the sump
wrench tool (not included), from the
filter head by rotating the sump as
shown in the below illustration. 
Be careful, the sump may be full 
of water. Be sure to keep the large
o-ring seal.

If you are replacing a filter cartridge,
remove and discard the used filter
cartridge.

Be sure the inside of the sump is
clean. Thoroughly wash the inside 
of the sump with hot, soapy water 
and rinse.

Remove the wrapper from the new
filter cartridge and insert the filter
cartridge in the sump. Some cartridges
fit either way, while others fit only one
way. Observe markings on the cartridge.

NOTE: 

The Water Filtration system 

uses different types of filter cartridges.
Be sure to install them correctly. 

Lightly lubricate the o-ring seal in the
sump with clean food grade silicone
grease (silicone grease is available
through GE Parts and Service:

1.800.626.2002

, Part number 

WS60X10005

). 

Be sure it is fully seated in its groove. 

Hold the sump up to the filter head,
aligning the center hole in the
cartridge with the protrusion on the
bottom of the head. Failure to obtain
proper alignment may cause damage
to the filter and/or filtration system
which will degrade filter performance.

Being careful not to cross-thread,
rotate the sump onto the filter head
and tighten securely by hand.

NOTE:

If the sump will not tighten up

to the head or if you feel resistance,
you may have the cartridge in upside
down or misaligned. Take the
cartridge out and check for correct
orientation and reassemble.

Turn on the filtered water faucet.
Then, slowly open the water supply/
saddle valve and allow the filter
housing to fill. 

Close the filtered water faucet. Then,
check for leaks between the sump and
the head.

NOTE:

If leaking, turn off the water

supply and turn on the filtered water
faucet. Disassemble the filter housing
and check the o-ring for cuts, flat
spots, etc., and sealing surfaces for
foreign material. Clean the o-ring and
lightly lubricate with clean silicone
grease. Carefully press into the groove
in the sump. Reassemble and check
for leaks.

The filter cartridges contain activated
carbon. When new, turn on the
filtered water faucet for five minutes 
to flush the system. 

Place filter change label on sump,
inside cabinet door or in another
convenient location. Write in date 
of filter change for future reference.
Filters should be changed every 
six months.

12

11

10

9

8

7

6

5

4

3

2

1

O-ring seal

Cartridge

Sump I

Label

Head

OUTLET

INLET

Bracket

Summary of Contents for SmartWater GX1S01C

Page 1: ...ure Temperature FXUTC Taste and Odor 1 0 gpm 3000 gal or 6 months 40 125 psi 40 100 F FXULC rev 2 Lead and Cyst 0 6 gpm 600 gal or 6 months 40 125 psi 40 100 F SAFETY PRECAUTIONS Check with your local public works department for plumbing codes You must follow these guidelines as you install the Water Filtration system Use the Water Filtration system on a potable safe to drink home COLD water suppl...

Page 2: ...ctions included with kit Faucet UCFCTBL or UCFCTWW Sump Wrench UCWRNCH recommended 1 Shut off cold water supply 2 Make connections as shown 3 Fully open filtered water faucet 4 Slowly turn on water supply valve and check for leaks 5 Close faucet when water flow is smooth Filtered water faucet Sink Hot Cold Water supply valve Washer Adapter Nut Water in Water out Tubing Insert Mounting screw 2 Nut ...

Page 3: ...different types of filter cartridges Be sure to install them correctly Lightly lubricate the o ring seal in the sump with clean food grade silicone grease silicone grease is available through GE Parts and Service 1 800 626 2002 Part number WS60X10005 Be sure it is fully seated in its groove Hold the sump up to the filter head aligning the center hole in the cartridge with the protrusion on the bot...

Page 4: ...rtified for cyst reduction may be used on disinfected water that may contain filterable cysts Damage to the product caused by accident fire floods or acts of God Incidental or consequential damage caused by possible defects with this appliance its installation or repair For how long after the original purchase One 1 year How do I make a warranty claim Return to the retailer from which it was purch...

Page 5: ...filtration d eau uniquement sur une canalisation d eau potable FROIDE La cartouche de filtration ne purifie pas l eau et ne peut pas rendre potable l eau qui ne l est pas Ne pas utiliser ce produit sur une canalisation d eau chaude 100 F maximum Protéger le produit contre le gel et les intempéries emplacement d installation approprié La congélation d eau dans le produit l endommagerait Le système ...

Page 6: ... instructions complètes incluses Robinet UCFCTBL ou UCFCTWW Clé pour corps de filtre UCWRNCH recommandée 1 Fermer l arrivée d eau froide 2 Exécuter les raccordements selon l illustration 3 Ouvrir complètement le robinet d eau filtrée 4 Ouvrir lentement l arrivée d eau inspecter pour rechercher les fuites 5 Fermer le robinet lorsque le débit est devenu régulier Robinet d eau filtrée Évier Eau chaud...

Page 7: ...r légèrement le joint torique du corps du filtre avec une graisse aux silicones de qualité alimentaire graisse aux silicones n WS60X10005 disponible auprès de GE pièces et service tél 1 800 626 2002 Veiller à ce que le joint soit parfaitement en place dans la rainure Tenir le corps de filtre sous la tête de montage aligner le trou central de la cartouche avec la pièce en saillie sous la tête Un dé...

Page 8: ...mes homologués pour une réduction des microbes peuvent être utilisés après désinfection de l eau pouvant contenir des microbes filtrables Tout dommage causé au produit par accident incendie inondation ou acte de Dieu Tout dommage fortuit ou indirect causé par des défauts éventuels de cet appareil son installation ou les réparations effectuées Quelle est la durée de la garantie après l achat Un an ...

Page 9: ...l sistema de Filtración de Agua solamente en una línea de agua FRIA de hogar que sea potable segura para ser bebida El cartucho del filtro no purificará el agua o la hará segura para tomar No lo use en una línea de agua caliente 100 F máx Instale o guarde donde no estará expuesto a temperaturas bajo el punto de congelación o expuesto a cualquier tipo de clima El agua que se congele en el sistema l...

Page 10: ...n el juego Llave de agua UCFCTBL o UCFCTWW Llave inglesa para receptáculos UCWRNCH recomendada 1 Cierre la línea de agua fría 2 Haga las conexiones como se muestra 3 Abra completamente la llave del agua filtrada 4 Lentamente abra la válvula del paso del agua y vea que no hayan goteras 5 Cierre la llave cuando el paso del agua es suave Llave de agua filtrada Fregadero Caliente Fría Válvula de línea...

Page 11: ...e Filtración de Agua usa diferentes tipos de cartuchos de filtro Asegúrese de instalarlos correctamente Lubricar ligeramente el sello de anillo tórico en el sumidero con grasa de silicona limpia de calidad alimenticia GE Parts and Service 1 800 626 2002 tiene disponible la grasa de silicona número de parte WS60X10005 Cerciórese que esté bien asentada en su ranura Sujete el receptáculo hacia la cab...

Page 12: ...nivel de quistes pueden ser usados en agua desinfectada que pueda contener quistes que se puedan filtrar Daños causados al producto debido a accidentes incendio inundaciones o actos de la naturaleza Daños secundarios o por consecuencia causados por posibles defectos en el producto su instalación o reparación Por cuánto tiempo después de la compra Un año Cómo hago la reclamación de la garantía Devu...

Reviews: