34
GE Oil & Gas
ValVue SVI II AP Quick Start
Remote Position Sensor Mounting Instructions
Tools Needed
7/16” open end wrench
6 mm hex wrench
2.5 mm hex wrench
Blade screwdriver
NOTE
The instructions below cover mounting the Remote Mount
Sensor to both reciprocating and rotary actuators. The two
mounting kits share only one part; the ¼-20 hex head cap
screws. Although the assembly steps are similar, differences
are noted. Refer to the Figure
19 on page
35 when reading
these instructions for proper orientation.
1. Fasten the mounting bracket to the actuator yoke:
For reciprocating actuators, use the (2) 5/16-18 hex head bolts supplied.
For rotary actuators, use the (2) 5/16-18 hex socket countersunk screws
supplied.
2. Connect the Remote Mount Sensor (RMS) to the mounting bracket using (4)
¼-20 hex head cap screws. Orient the RMS as shown in Figure
19, such that
the conduit opening faces the ground.
3. Attach the feedback lever to the RMS output shaft:
For reciprocating mounting:
a. Slip the feedback lever onto the RMS output shaft, and thread the M5 set
screw into the hole. Ensure to align the setscrew hole of the feedback lever
with the flat of the RMS output shaft such that the setscrew contacts the flat.
b. Connect the take-off rod to the split clamp of the actuator stem.
c. Connect one end of the turnbuckle to the feedback lever, and the other end
to the take-off rod. (Refer to Table
5 on page
35 for turnbuckle length.)
For rotary mounting:
a. Connect the feedback lever (with the pin) to the actuator shaft (protruding
from the actuator yoke) using the supplied hardware. This hardware
includes a spacer, a spring washer and a ¼-28 hex head cap screw.
b. Attach the second feedback lever (with the slot) to the RMS output shaft and
at the same time; insert the pin of the first feedback lever into the slot. It may
be necessary to loosen some of the parts in order to get everything to align
properly.
c. Thread the M4 socket head cap screw into the setscrew hole of the second
feedback lever making sure it contacts the flat of the RMS output shaft.
Summary of Contents for SVI II AP-2
Page 6: ...GE Oil Gas SVI II AP Quick Start Guide 6 ...
Page 10: ...10 GE Oil Gas ValVue SVI II AP Quick Start This page intentionally left blank ...
Page 64: ...64 GE Oil Gas ValVue SVI II AP Quick Start This page intentionally left blank ...
Page 90: ...90 GE Oil Gas ValVue SVI II AP Quick Start Spare Parts ...
Page 91: ...91 Specifications and Spare Parts ...