ES-699 Rev U
Page 8 of 17
7
Description of Intrinsically Safe Markings
Applicable Model Numbers:
SVI2-abcdefgh, where
“a”
thru
“h”
can take on the following values:
a = 1 ; b = 1 ; c = 1, 2 ; d = 1, 2 ; e = 3 ; f = 1 ; g = 1,2 ; h = 3,4
The label may not appear exactly as shown, but must contain the following
information listed below. Other information is allowed on the label.
II 3G Ex nL IIC T6
Avon MA USA
WARNING
REFER TO ES-699 FOR ADDITIONAL CAUTIONS OR WARNINGS
Supply Connection Wiring Rated for 5ºC Above Max Ambient
MODEL: SVI2-1bcdefgh
30 Volts, 4-20mA, 80 PSI
Type 4X-IP66
DO NOT OPEN EVEN WHEN ISOLATED WHEN
FLAMMABLE / DUST ATMOSPHERES ARE
PRESENT
ZELM 05ATEX0280X
SN-nnywwnnnn
Operating Temp
–
40ºC to +85ºC
T6 Ta=60ºC, T5 Ta=75ºC, T4 Ta=85ºC
055201-188-779
Rev
E
PERMANENTLY MARK THE PROTECTION TYPE
CHOSEN. ONCE THE TYPE HAS BEEN MARKED, IT
CAN NOT BE CHANGED.
II 2G Ex ia IIC T6
0518
Ex ia IIC T6
IECEx FMG 07.0007x
IECEx
II 2D Ex iaD 20 T96°C
7.1
Manufacturers Name and Location
AVON
MA
USA
7.2
Markings:
(ATEX)
{Explosionproof Mark}
{European
Community
Compliance
Mark}
ZELM
{Certifying
Agency}
05ATEX0280X
{Certificate
Number}
II 2G Ex ia IIC T6
{Intrinsically Safe, gas}
II 2D Ex iaD 20 T96°C
{Intrinsically Safe, dust}
II 3G Ex nL IIC T6
{Limited Engery, gas}
0518
80
GE Oil & Gas
ValVue SVI II AP Quick Start
Summary of Contents for SVI II AP-2
Page 6: ...GE Oil Gas SVI II AP Quick Start Guide 6 ...
Page 10: ...10 GE Oil Gas ValVue SVI II AP Quick Start This page intentionally left blank ...
Page 64: ...64 GE Oil Gas ValVue SVI II AP Quick Start This page intentionally left blank ...
Page 90: ...90 GE Oil Gas ValVue SVI II AP Quick Start Spare Parts ...
Page 91: ...91 Specifications and Spare Parts ...