Chapter 4
– Functions
GE Reason Switches
58
REASON SWITCHES-TM-EN-3
It is possible to define the repetition time of the packet and the time that a given port
will remain off if a loop is detected. Besides, each port can be freely set to have the
function enabled and send or not loop detection packets. If a loop is detected, there
are three actions allowed:
Shutdown port;
Shutdown and log;
Log only.
If the Log option is enabled, a log server must be configured to send the log
messages informing the loop detection of a given port must be set.
Summary of Contents for T1000
Page 2: ......
Page 11: ...Figure 97 T1000 dimensions 298 Figure 98 S2020 and S2024G dimensions 299...
Page 12: ......
Page 41: ...Chapter 3 Hardware Design GE Reason Switches REASON SWITCHES TM EN 3 41 Figure 4 S2024G Switch...
Page 256: ......
Page 274: ......