A-2
T35 Transformer Protection System
GE Multilin
A.1 PARAMETER LISTS
APPENDIX A
A
6212
SRC 2 Ic RMS
Amps
Source 2 phase C current RMS
6214
SRC 2 In RMS
Amps
Source 2 neutral current RMS
6216
SRC 2 Ia Mag
Amps
Source 2 phase A current magnitude
6218
SRC 2 Ia Angle
Degrees
Source 2 phase A current angle
6219
SRC 2 Ib Mag
Amps
Source 2 phase B current magnitude
6221
SRC 2 Ib Angle
Degrees
Source 2 phase B current angle
6222
SRC 2 Ic Mag
Amps
Source 2 phase C current magnitude
6224
SRC 2 Ic Angle
Degrees
Source 2 phase C current angle
6225
SRC 2 In Mag
Amps
Source 2 neutral current magnitude
6227
SRC 2 In Angle
Degrees
Source 2 neutral current angle
6228
SRC 2 Ig RMS
Amps
Source 2 ground current RMS
6230
SRC 2 Ig Mag
Amps
Source 2 ground current magnitude
6232
SRC 2 Ig Angle
Degrees
Source 2 ground current angle
6233
SRC 2 I_0 Mag
Amps
Source 2 zero-sequence current magnitude
6235
SRC 2 I_0 Angle
Degrees
Source 2 zero-sequence current angle
6236
SRC 2 I_1 Mag
Amps
Source 2 positive-sequence current magnitude
6238
SRC 2 I_1 Angle
Degrees
Source 2 positive-sequence current angle
6239
SRC 2 I_2 Mag
Amps
Source 2 negative-sequence current magnitude
6241
SRC 2 I_2 Angle
Degrees
Source 2 negative-sequence current angle
6242
SRC 2 Igd Mag
Amps
Source 2 differential ground current magnitude
6244
SRC 2 Igd Angle
Degrees
Source 2 differential ground current angle
6272
SRC 3 Ia RMS
Amps
Source 3 phase A current RMS
6274
SRC 3 Ib RMS
Amps
Source 3 phase B current RMS
6276
SRC 3 Ic RMS
Amps
Source 3 phase C current RMS
6278
SRC 3 In RMS
Amps
Source 3 neutral current RMS
6280
SRC 3 Ia Mag
Amps
Source 3 phase A current magnitude
6282
SRC 3 Ia Angle
Degrees
Source 3 phase A current angle
6283
SRC 3 Ib Mag
Amps
Source 3 phase B current magnitude
6285
SRC 3 Ib Angle
Degrees
Source 3 phase B current angle
6286
SRC 3 Ic Mag
Amps
Source 3 phase C current magnitude
6288
SRC 3 Ic Angle
Degrees
Source 3 phase C current angle
6289
SRC 3 In Mag
Amps
Source 3 neutral current magnitude
6291
SRC 3 In Angle
Degrees
Source 3 neutral current angle
6292
SRC 3 Ig RMS
Amps
Source 3 ground current RMS
6294
SRC 3 Ig Mag
Amps
Source 3 ground current magnitude
6296
SRC 3 Ig Angle
Degrees
Source 3 ground current angle
6297
SRC 3 I_0 Mag
Amps
Source 3 zero-sequence current magnitude
6299
SRC 3 I_0 Angle
Degrees
Source 3 zero-sequence current angle
6300
SRC 3 I_1 Mag
Amps
Source 3 positive-sequence current magnitude
6302
SRC 3 I_1 Angle
Degrees
Source 3 positive-sequence current angle
6303
SRC 3 I_2 Mag
Amps
Source 3 negative-sequence current magnitude
6305
SRC 3 I_2 Angle
Degrees
Source 3 negative-sequence current angle
6306
SRC 3 Igd Mag
Amps
Source 3 differential ground current magnitude
6308
SRC 3 Igd Angle
Degrees
Source 3 differential ground current angle
6336
SRC 4 Ia RMS
Amps
Source 4 phase A current RMS
6338
SRC 4 Ib RMS
Amps
Source 4 phase B current RMS
6340
SRC 4 Ic RMS
Amps
Source 4 phase C current RMS
Table A–1: FLEXANALOG DATA ITEMS (Sheet 2 of 12)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Summary of Contents for T35 UR Series
Page 10: ...x T35 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 48: ...2 18 T35 Transformer Protection System GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Page 314: ...5 192 T35 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 338: ...6 24 T35 Transformer Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 350: ...7 12 T35 Transformer Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Page 366: ...8 16 T35 Transformer Protection System GE Multilin 8 2 CYBERSENTRY 8 SECURITY 8 ...
Page 406: ...A 14 T35 Transformer Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 540: ...D 10 T35 Transformer Protection System GE Multilin D 1 IEC 60870 5 104 PROTOCOL APPENDIX D D ...
Page 552: ...E 12 T35 Transformer Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Page 560: ...F 8 T35 Transformer Protection System GE Multilin F 3 WARRANTY APPENDIX F F ...