Tools required:
Wire stripper/cutter
Tape measure
Electrical grade silicone
Cordless drill
Components required:
UL approved 18 AWG (0.82mm
2
)
supply wire
End Caps
Weather Boxes
22 AWG (0.33mm
2
) tie-wire
Light Guide Mounting Clips
#6, #8 or #10 (M2, M3 or M4) self
drilling pan headed screws
UL approved twist-on wire
connectors fitting both 18 and 20
AWG wire (0.82mm
2
, 0.52mm
2
)
Tetra 24 Volt Power Supply
Tetra
®
®
Contour LS
Optional: Tetra
®
Contour LS
extension
Tools and Components
Tetra
®
Contour LS
LED Lighting System
GE
Lighting Solutions
Installation Guide
imagination at work
24
Volt
)
m
4
4
.
2
(
t
e
e
f
8
)
m
m
6
0
4
(
s
e
h
c
n
i
6
1
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
7
6
8
9
10
1
2
3
4
1
2
3
4
Symptom
Solution
All sections are OFF
• Check
AC input connection and/or check circuit breaker.
• Check wi
re connection(s) at the Tetra Contour LS section and power supply for improper
termination(s) or short circuits. Properly terminate or replace the wire connection(s).
• Check that connections a
re the white wire with red stripe (+) of the LED strip to the red wire (+) of the
power supply and the white wire (-) of the LED strip to the black wire (-) of the power supply.
Some LEDs appear dim
• Ensu
re the overall length of the Tetra Contour LS does not exceed the maximum load.
•
Ensure the length of supply wire from the power supply is equal to or below the recommended remote
mounting distance.
• Ma
ke sure that all LED light engines have the same suffix code (suffix code is located on the
box label).
Some of the sections
are not illuminated
• Check wi
re connection(s) at the Tetra Contour LS section and power supply for improper
termination(s) or short circuits. Properly terminate or replace the wire connection(s).
• Check that connections a
re the white wire with red stripe (+) of the LED strip to the red wire (+) of the
power supply and the white wire (-) of the LED strip to the black wire (-) of the power supply.
Troubleshooting
RISK OF ELECTRIC SHOCK:
•
Turn power OFF before inspection, installation
or removal.
• P
roperly ground Tetra Power Supply enclosure.
RISK OF FIRE:
• Follow all NEC and local codes.
• Use only UL app
roved wire for input/output connections.
Minimum size 18 AWG (0.82 mm
2
)
WARNING!
Conforms to the following standards:
Optional
–Attaching Tetra Contour LS to Tetra Contour
2
Splice the white wire with red stripe (+) of Tetra Contour LS
to the two outside wires (+) of Tetra Contour and splice the
white wire (-) of Tetra Contour LS to the center wire (-) of
Tetra Contour.
Tetra Contour LS
Tetra Contour
Outside wires (+)
Center wire ( - )
SIGN050
- R120210
1
When connecting Tetra Contour LS to Tetra Contour,
separate wires and identify conductors as positive (+)
and negative (–). Strip ends back 0.5 in. (12mm).
Tetra Contour LS
+
+
+ –
–
Tetra Contour
White wire with
red stripe
White wire with red stripe (+)
White wire ( - )
NOTE:
Weather box is required for all outdoor
electrical connections.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [ A ] est conforme à la NMB-005 du Canada.
GE Lighting Solutions
• 1-888-M
Y-GE-LED
• w
ww.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
GE Lighting Solutions is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting Solutions. The GE brand and logo are trademarks of the General Electric Company.
© 2010 GE Lighting Solutions. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.