2
Power Supply Installation
Black (-)
Green with
yellow stripe
White (+)
Connect the AC line to the black
(line) and white (neutral) input
wires of the power supply using
18-14 AWG (0.82-2.08 mm
2
) twist-on
wire connectors. Properly ground
(green wire with yellow stripe) power
supply in accordance with National
Electric Code (NEC) Article 600.
1
Power Supply
Conduit
Power Supply
input wires
AC Line
Run AC line through conduit and
attach conduit to outdoor-rated/UL
approved enclosure. Attach power
supply to enclosure.
Connect the red stripe wire (+) of the
LED strip to the red wire (+) of the
power supply. Connect the white
wire (-) of the LED strip to the black
wire (-) of the power supply.
2
3
To power supply
Red (+)
Red stripe (+)
White (-)
Black (-)
NOTE:
All electrical connections
should be made within the letter.
4
Mount Power Supply in a horizontal
orientation with a minimum of one
screw per mounting plate (two
screws per power supply) with the
base in contact with the mounting
surface in accordance with the
power supply spacing requirements
described above.
5
Tighten liquid-tight fittings and
properly replace cover on junction
box to ensure a water-tight seal. If
not protected from the weather, the
output connections may be sealed
with electrical grade silicone.
NOTE:
Exceeding maximum load per bank will cause the power supply to shut down. Once the excess load is removed, cycle the
input power to restart the power supply.
NOTE:
To avoid overloading this
power supply with LED modules,
please refer to the specific module
loading guides.
CAUTION/ATTENTION
RISK OF INJURY
• While performing installations described, gloves, safety
glasses or goggles should be worn.
RISQUES DE BLESSURE
• Lors de l’exécution des installations décrites, des gants, des lunettes de
sécurité ou des lunettes de protection doivent être portées.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
• Disconnect power at fuse box or circuit breaker before servicing
or installing product.
• Properly ground Tetra
®
power supply.
RISK OF FIRE
• Use only approved wire for input/output connection. Minimum
size 18 AWG (0.82 mm
2
).
• Follow all local codes.
• Application considerations potentially requiring additional
spacing include high ambient temperature seen by the
power supply, poor contact with a heat dissipating material,
inadequate ventilation, or direct exposure to sun.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant
l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre le bloc d’alimentation Tetra
®
.
RISQUES D’INCENDIE
• N’utilisez que des fils approuvés pour les entrées/sorties de connexion.
Taille minimum 18 AWG (0.82 mm
2
).
• Respectez tous les codes locaux.
• Certaines applications pourraient requérir un espacement additionnel, p.
ex. une température ambiante élevée autour du bloc d’alimentation, un
mauvais contact avec une matière dissipatrice de chaleur, une ventilation
inadéquate ou une exposition directe au soleil.