background image

2

Power Supply Installation

Black (-)

Green with 

yellow stripe

White (+)

Connect the AC line to the black 

(line) and white (neutral) input 

wires of the power supply using 

18-14 AWG (0.82-2.08 mm

2

) twist-on 

wire connectors. Properly ground 

(green wire with yellow stripe) power 

supply in accordance with National 

Electric Code (NEC) Article 600. 

1

Power Supply

Conduit

Power Supply 

input wires

AC Line

Run AC line through conduit and 

attach conduit to outdoor-rated/UL 

approved enclosure. Attach power 

supply to enclosure.

Connect the red stripe wire (+) of the 

LED strip to the red wire (+) of the 

power supply. Connect the white 

wire (-) of the LED strip to the black 

wire (-) of the power supply.

2

3

To power supply 

Red (+)

Red stripe (+)

White (-)

Black (-)

NOTE:

  All electrical connections 

should be made within the letter.

4

Mount Power Supply in a horizontal 

orientation with a minimum of one 

screw per mounting plate (two 

screws per power supply) with the 

base in contact with the mounting 

surface in accordance with the 

power supply spacing requirements 

described above.

5

Tighten liquid-tight fittings and 

properly replace cover on junction 

box to ensure a water-tight seal. If 

not protected from the weather, the 

output connections may be sealed 

with electrical grade silicone.

NOTE: 

Exceeding maximum load per bank will cause the power supply to shut down. Once the excess load is removed, cycle the 

input power to restart the power supply.

NOTE:

 To avoid overloading this 

power supply with LED modules, 

please refer to the specific module 

loading guides.

 CAUTION/ATTENTION

RISK OF INJURY
•  While performing installations described, gloves, safety 

glasses or goggles should be worn.

RISQUES DE BLESSURE
•  Lors de l’exécution des installations décrites, des gants, des lunettes de 

sécurité ou des lunettes de protection doivent être portées.

 WARNING/AVERTISSEMENT

RISK OF ELECTRIC SHOCK
•  Disconnect power at fuse box or circuit breaker before servicing 

or installing product.

•  Properly ground Tetra

®

 power supply.

RISK OF FIRE
•  Use only approved wire for input/output connection. Minimum 

size 18 AWG (0.82 mm

2

).

•  Follow all local codes.

•  Application considerations potentially requiring additional 

spacing include high ambient temperature seen by the 

power supply, poor contact with a heat dissipating material, 

inadequate ventilation, or direct exposure to sun.

RISQUES DE DÉCHARGES ÉLECTRIQUES
•  Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant 

l’entretien ou l’installation du produit.

•  Assurez-vous de correctement mettre à terre le bloc d’alimentation Tetra

®

.

RISQUES D’INCENDIE
•  N’utilisez que des fils approuvés pour les entrées/sorties de connexion. 

Taille minimum 18 AWG (0.82 mm

2

).

•  Respectez tous les codes locaux.
•  Certaines applications pourraient requérir un espacement additionnel, p. 

ex. une température ambiante élevée autour du bloc d’alimentation, un 

mauvais contact avec une matière dissipatrice de chaleur, une ventilation 

inadéquate ou une exposition directe au soleil. 