All trademarks are the property of their respective owners. Information provided is subject to
change without notice. All values are design or typical values when measured under laboratory
conditions. Current, powered by GE is a business of the General Electric Company.
© 2019 GE.
(Rev
)
05/30/19
www.currentbyge.com
Power Supply Specifications
Performance Data
Min
Typical
Max
Input Voltage (VAC)
Input Frequency (Hz)
Input Current (A)
THD
PF
Output Voltage (VDC)
Output Current (ADC)
Output Power (W)
Environmental Operating Temperature Range
Environmental Humidity (non-condensing)
Environmental Storage Temperature Range
Environmental Rating
Dimensions
Conforms to the following standards:
This product is intended to be used as a lamp control gear that is installed after the mains control switch.
90
100-240
264
-
50/60
-
-
-
-
23.0
24.3
25.6
-
-
3.3
-
-
80
-
-
20
0.9
-
12 in. x 2 in. x 1.25 in. (307 mm x 52 mm x 32 mm)
-40°C
+25°C
+60°C*
0%
-
95%
-40°C
-
+85°C
*Maximum case temperature is °C
80
Symptom
Solution
All letters are OFF
• Recycle AC power, turn it off, then turn on again.
• If still off, check the power supply DC output voltage using a voltmeter. It should be nominally V.
»
If there is DC output, inspect and correct all DC wire damage/polarity issues; If no issue is found, replace the
OFF-module string.
»
If there is no DC output, have a licensed electrician check the input AC voltage and if there is correct AC voltage,
replace the power supply.
»
If there is no AC voltage, correct the upstream AC issue.
Some LEDs appear dim
• Ensure the overall length of the Tetra
®
LED System does not exceed the maximum load.
• Ensure the length of supply wire is equal to or below the recommended remote mounting distance.
Some of the letters
are not illuminated
• Inspect and correct the wires of the non-illuminated letters for damage/polarity issues; If no issues are found, see the
troubleshooting solution for “All letters are OFF.”
Shadows
• Re-route supply wire and secure to the back of the can with electrical grade RTV silicone. Adjust wire connector
orientation so that it does not cover any LEDs.
• Adjust LED layout to ensure uniformity of illumination of the face of the letter.
Troubleshooting
SIGN201
GE2022-3612
IP66 Rated
24
OPTIONAL
A Weather Box (GEXNWB2) may be used to house and seal Class 2
connections.
A) Insert wire connectors into weather box. Fill with electrical grade
silicone and close box.
B) Secure the weather box using a #6 or #8 (M2 or M3) screw.
Weather box
can be painted
A
B
Light engine