Critical Power
Modifications reserved
Page 11/92
GE_UPS_USM_TLE_SUL_M62_1M0_2US_V010.docx
User Manual
TLE Series 625 - 750 - 1000 UL S2
3
INTRODUCTION
The
TLE Series 625 - 750 - 1000
Uninterruptible Power Supply
(UPS) provides the energy supply for
critical loads which need a reliable, continuous free from voltage disturbances and frequency
fluctuations supply.
In case the power provided by the
Utility Fails
, or exceeds the permitted tolerances, the power to supply
the
Load
is provided by the
Battery
for the specified time at the rated
Load
(or longer at a reduced
Load
)
or until the
Utility
power returns.
TLE Series 625 - 750 - 1000
is a truly VFI double conversion
Uninterruptible Power
Supply
(UPS), equipped with automatic bypass, where the
Load
is normally supplied
by the
Inverter
.
If the
Inverter
is not able to supply the required
Output Voltage
, or when overload or
short-circuit on the output occur, the
Load
is instantly transferred to the
Utility
via
the
Automatic Bypass
.
The UPS automatically returns to normal mode when the failure condition is
restored.
TLE Series 625 - 750 - 1000
can be configured, if chosen, for the
eBoost™ Operation
Mode
(Option - High efficiency: up to 99% / Fast power transfer: <2ms) permitting
maximum energy saving.
KEY FEATURES
:
More Critical equipment supported
Rated at 1 Power Factor,
TLE Series 625 - 750 - 1000
delivers more real power than other UPS in the
market.
With today’s trend toward power factor corrected loads,
TLE Series 625 - 750 - 1000
can support more
total
Load
than any other UPS available, allowing you to support a greater number of today’s enterprise
computing
Power Factor Corrected (PFC)
equipment.
High Efficiency
Thanks to type
Advanced Neutral Point Clamped
three level
IGBT
technology,
TLE Series 625 - 750 - 1000
guarantees a high overall performance.
Intelligent Energy Management
(IEM)
combined with
RPA
, results in the most cost efficient and reliable
UPS solution in the industry.
Fully digital
Digital Signal Processor (DSP)
,
Flash memory
and
Advanced Neutral Point Clamped
are the technology
corner stones of a new age of power quality and power reliability.
RPA™ - Redundant Parallel Architecture™ Parallel System
GE
provides a unique technology called
Redundant Parallel Architecture™ (RPA™)
that can parallel
Uninterruptible Power Supply (UPS) modules with true redundancy.
With
RPA™
, there is no need for external electronics or switches to control the UPS modules in the
parallel system.
One of the UPS modules in the system arbitrarily takes a leadership role, while the other UPS modules
have access to all control parameters.
If one UPS fails to operate, the load is automatically redistributed among the others.
If the lead UPS fails to operate then a different UPS automatically takes on the leadership role.
The
RPA™
systems are designed to have no single points of failure, ensuring the highest level of power
protection for critical loads.
Extremely flexible
Tailor made power protection to meet your individual installation requirements;
TLE Series 625 - 750 -
1000
offers various options like
EMC filter
and our comprehensive
software
for mission control and data
protection to cover all your application needs.