7-50
745 Transformer Management Relay
GE Multilin
7.4 MODBUS MEMORY MAP
7 COMMUNICATIONS
7
F24
con’t
xxxx 0000 0100 0011
67 = Logic Input 2
xxxx 0000 0100 0100
68 = Logic Input 3
xxxx 0000 0100 0101
69 = Logic Input 4
xxxx 0000 0100 0110
70 = Logic Input 5
xxxx 0000 0100 0111
71 = Logic Input 6
xxxx 0000 0100 1000
72 = Logic Input 7
xxxx 0000 0100 1001
73 = Logic Input 8
xxxx 0000 0100 1010
74 = Logic Input 9
xxxx 0000 0100 1011
75 = Logic Input 10
xxxx 0000 0100 1100
76 = Logic Input 11
xxxx 0000 0100 1101
77 = Logic Input 12
xxxx 0000 0100 1110
78 = Logic Input 13
xxxx 0000 0100 1111
79 = Logic Input 14
xxxx 0000 0101 0000
80 = Logic Input 15
xxxx 0000 0101 0001
81 = Logic Input 16
xxxx 0000 0101 0010
82 = Virtual Input 1
xxxx 0000 0101 0011
83 = Virtual Input 2
xxxx 0000 0101 0100
84 = Virtual Input 3
xxxx 0000 0101 0101
85 = Virtual Input 4
xxxx 0000 0101 0110
86 = Virtual Input 5
xxxx 0000 0101 0111
87 = Virtual Input 6
xxxx 0000 0101 1000
88 = Virtual Input 7
xxxx 0000 0101 1001
89 = Virtual Input 8
xxxx 0000 0101 1010
90 = Virtual Input 9
xxxx 0000 0101 1011
91 = Virtual Input 10
xxxx 0000 0101 1100
92 = Virtual Input 11
xxxx 0000 0101 1101
93 = Virtual Input 12
xxxx 0000 0101 1110
94 = Virtual Input 13
xxxx 0000 0101 1111
95 = Virtual Input 14
xxxx 0000 0110 0000
96 = Virtual Input 15
xxxx 0000 0110 0001
97 = Virtual Input 16
xxxx 0000 0110 0010
98 = Output Relay 1
xxxx 0000 0110 0011
99 = Output Relay 2
xxxx 0000 0110 0100
100 = Output Relay 3
xxxx 0000 0110 0101
101 = Output Relay 4
xxxx 0000 0110 0110
102 = Output Relay 5
xxxx 0000 0110 0111
103 = Output Relay 6
xxxx 0000 0110 1000
104 = Output Relay 7
xxxx 0000 0110 1001
105 = Output Relay 8
xxxx 0000 0110 1010
106 = Self-Test Relay
xxxx 0000 0110 1011
107 = Virtual Output 1
xxxx 0000 0110 1100
108 = Virtual Output 2
xxxx 0000 0110 1101
109 = Virtual Output 3
xxxx 0000 0110 1110
110 = Virtual Output 4
xxxx 0000 0110 1111
111 = Virtual Output 5
xxxx 0000 0111 0000
112 = Setpoint Group 1
xxxx 0000 0111 0001
113 = Setpoint Group 2
xxxx 0000 0111 0010
114 = Setpoint Group 3
xxxx 0000 0111 0011
115 = Setpoint Group 4
xxxx 0000 0111 0100
116 = Test Mode
xxxx 0000 0111 0101
117 = Simulation Disabled
xxxx 0000 0111 0110
118 = Simulation Prefault
xxxx 0000 0111 0111
119 = Simulation Fault
xxxx 0000 0111 1000
120 = Simulation Playback
xxxx 0000 0111 1001
121 = Logic Input Reset
xxxx 0000 0111 1010
122 = Front Panel Reset
Table 7–6: 745 DATA FORMATS (Sheet 5 of 25)
CODE
APPLICABLE BITS
DEFINITION
F24
con’t
xxxx 0000 0111 1011
123 = Comm Port Reset
xxxx 0000 0111 1100
124 = Manual Trace Trigger
xxxx 0000 0111 1101
125 = Auto Trace Trigger
xxxx 0000 0111 1110
126 = Control Power
xxxx 0000 0111 1111
127 = Logic Input Power
xxxx 0000 1000 0000
128 = Analog Output Power
xxxx 0000 1000 0001
129 = Unit Not Calibrated
xxxx 0000 1000 0010
130 = EEPROM Memory
xxxx 0000 1000 0011
131 = Real-Time Clock
xxxx 0000 1000 0100
132 = Not Used
xxxx 0000 1000 0101
133 = Emulation Software
xxxx 0000 1000 0110
134 = Int Temperature
xxxx 0000 1000 0111
135 = Flexlogic Equation
xxxx 0000 1000 1000
136 = DSP Processor
xxxx 0000 1000 1001
137 = Bad Xfmr Settings
xxxx 0000 1000 1010
138 = IRIG-B Signal
xxxx 0000 1000 1011
139 = Setpt Access Denied
xxxx 0000 1000 1100
140 = Aging factor Limit
xxxx 0000 1000 1101
141 = Ambient Temperature
xxxx 0000 1000 1110
142 = Tap Changer Failure
F25
16 bits
2's COMPLEMENT SIGNED VALUE,
3 DECIMAL PLACES
Example: –1.234 stored as –1234
F26
16 bits
ANALOG OUTPUT RANGE
0000 0000 0000 0000
0 = 0-1 mA
0000 0000 0000 0001
1 = 0-5 mA
0000 0000 0000 0010
2 = 4-20 mA
0000 0000 0000 0011
3 = 0-20 mA
0000 0000 0000 0100
4 = 0-10 mA
F27
16 bits
PHASE SEQUENCE
0000 0000 0000 0000
0 = ABC
0000 0000 0000 0001
1 = ACB
F28
16 bits
TRANSFORMER TYPE
0000 0000 0000 0000
0 = 2W (extn correction)
0000 0000 0000 0001
1 = Y/y0°
0000 0000 0000 0010
2 = Y/y180°
0000 0000 0000 0011
3 = Y/d30°
0000 0000 0000 0100
4 = Y/d150°
0000 0000 0000 0101
5 = Y/d210°
0000 0000 0000 0110
6 = Y/d330°
0000 0000 0000 0111
7 = D/d0°
0000 0000 0000 1000
8 = D/d60°
0000 0000 0000 1001
9 = D/d120°
0000 0000 0000 1010
10 = D/d180°
0000 0000 0000 1011
11 = D/d240°
0000 0000 0000 1100
12 = D/d300°
0000 0000 0000 1101
13 = D/y30°
0000 0000 0000 1110
14 = D/y150°
0000 0000 0000 1111
15 = D/y210°
0000 0000 0001 0000
16 = D/y330°
0000 0000 0001 0001
17 = Y/z30°
0000 0000 0001 0010
18 = Y/z150°
0000 0000 0001 0011
19 = Y/z210°
0000 0000 0001 0100
20 = Y/z330°
0000 0000 0001 0101
21 = D/z0°
0000 0000 0001 0110
22 = D/z60°
Table 7–6: 745 DATA FORMATS (Sheet 6 of 25)
CODE
APPLICABLE BITS
DEFINITION