GE Multilin
L90 Line Current Differential System
B-11
APPENDIX B
B.4 MEMORY MAPPING
B
FlexStates (Read Only)
0900
FlexState Bits (16 items)
0 to 65535
---
1
F001
0
Element States (Read Only)
1000
Element Operate States (64 items)
0 to 65535
---
1
F502
0
User Displays Actuals (Read Only)
1080
Formatted user-definable displays (16 items)
---
---
---
F200
(none)
Modbus User Map Actuals (Read Only)
1200
User Map Values (256 items)
0 to 65535
---
1
F001
0
Element Targets (Read Only)
14E0
Target Sequence
0 to 65535
---
1
F001
0
14E1
Number of Targets
0 to 65535
---
1
F001
0
Element Targets (Read/Write)
14E2
Target to Read
0 to 65535
---
1
F001
0
Element Targets (Read Only)
14E3
Target Message
---
---
---
F200
“.”
Digital Input/Output States (Read Only)
1500
Contact Input States (6 items)
0 to 65535
---
1
F500
0
1508
Virtual Input States (8 items)
0 to 65535
---
1
F500
0
1510
Contact Output States (4 items)
0 to 65535
---
1
F500
0
1518
Contact Output Current States (4 items)
0 to 65535
---
1
F500
0
1520
Contact Output Voltage States (4 items)
0 to 65535
---
1
F500
0
1528
Virtual Output States (6 items)
0 to 65535
---
1
F500
0
1530
Contact Output Detectors (4 items)
0 to 65535
---
1
F500
0
Input/Output States (Read Only)
1540
Remote Device States (2 items)
0 to 65535
---
1
F500
0
1542
Remote Input States (4 items)
0 to 65535
---
1
F500
0
1550
Remote Devices Online
0 to 1
---
1
F126
0 (No)
1551
Remote Double-Point Status Input 1 State
0 to 3
---
1
F605
3 (Bad)
1552
Remote Double-Point Status Input 2 State
0 to 3
---
1
F605
3 (Bad)
1553
Remote Double-Point Status Input 3 State
0 to 3
---
1
F605
3 (Bad)
1554
Remote Double-Point Status Input 4 State
0 to 3
---
1
F605
3 (Bad)
1555
Remote Double-Point Status Input 5 State
0 to 3
---
1
F605
3 (Bad)
Direct Input/Output States (Read Only)
15A0
Direct Input 1-1 State (8 items)
0 to 1
---
1
F108
0 (Off)
15A8
Direct Input 1-2 State (8 items)
0 to 1
---
1
F108
0 (Off)
15B0
Direct Input 1 State
0 to 65535
---
1
F500
0
15B1
Direct Input 2 State
0 to 65535
---
1
F500
0
Field Unit Input/Output States (Read Only)
15E0
Field unit contact input states (3 items)
0 to 65535
---
1
F500
0
15E3
Field unit contact input output operand states (8 items)
0 to 65535
---
1
F500
0
15EB
Field contact output physical states (8 items)
0 to 65535
---
1
F500
0
15F3
Field contact output current states (8 items)
0 to 65535
---
1
F500
0
15FB
Field contact output physical states (8 items)
0 to 65535
---
1
F500
0
1603
Field shared input states
0 to 65535
---
1
F500
0
1604
Field shared input channel states
0 to 65535
---
1
F500
0
1605
Field shared input test states
0 to 65535
---
1
F500
0
1606
Field shared output operand states
0 to 65535
---
1
F500
0
1607
Field latching output open operand states
0 to 65535
---
1
F500
0
1608
Field latching output close operand states
0 to 65535
---
1
F500
0
1609
Field latching output open driver states
0 to 65535
---
1
F500
0
160A
Field latching output close driver states
0 to 65535
---
1
F500
0
160B
Field latching output physical states
0 to 65535
---
1
F500
0
160C
Field unit online/offline states
0 to 65535
---
1
F500
0
160D
Fiedl RTD input trouble states
0 to 65535
---
1
F500
0
Table B–9: MODBUS MEMORY MAP (Sheet 3 of 72)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for UR Series L90
Page 652: ...A 16 L90 Line Current Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 772: ...B 120 L90 Line Current Differential System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Page 802: ...C 30 L90 Line Current Differential System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Page 812: ...D 10 L90 Line Current Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Page 824: ...E 12 L90 Line Current Differential System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Page 834: ...F 10 L90 Line Current Differential System GE Multilin F 3 WARRANTY APPENDIX F F ...
Page 846: ...xii L90 Line Current Differential System GE Multilin INDEX ...