CHAPTER 2: MODBUS COMMUNICATION
MEMORY MAP
UR SERIES – COMMUNICATIONS GUIDE
2-27
2
Source Voltage THD and Harmonics (Read Only) (4 or 6 Modules) (For F60, if order code has HIZ DSP, then 0
modules)
C70, F35, F60,
G30, G60
1F80
Source 1 Va THD
0 to 99.9
---
0.1
F001
0
"
1F81
Source 1 Va Harmonics - 2nd to 25th (24
items)
0 to 99.9
---
0.1
F001
0
"
1F99
Source 1 Vb THD
0 to 99.9
---
0.1
F001
0
"
1F9A
Source 1 Vb Harmonics - 2nd to 25th (24
items)
0 to 99.9
---
0.1
F001
0
"
1FB2
Source 1 Vc THD
0 to 99.9
---
0.1
F001
0
"
1FB3
Source 1 Vc Harmonics - 2nd to 25th (24
items)
0 to 99.9
---
0.1
F001
0
"
1FCB
...Repeated for Source 2
"
2016
...Repeated for Source 3
"
2061
...Repeated for Source 4
C70, F35
20AC
...Repeated for Source 5
"
20F7
...Repeated for Source 6
Breaker Flashover (Read/Write Setting) (1 or 2 Modules)
B30, C60, C70,
D60, F60, G60,
L60, L90, M60,
T60
2196
Breaker Flashover 1 Function
0 to 1
---
1
F102
0 (Disabled)
"
2197
Breaker Flashover 1 Side 1 Source
0 to 5
---
1
F167
0 (SRC 1)
"
2198
Breaker Flashover 1 Side 2 Source
0 to 6
---
1
F211
0 (None)
"
2199
Breaker Flashover 1 Status Closed A
0 to 4294967295
---
1
F300
0
"
219B
Breaker Flashover 1 Status Closed B
0 to 4294967295
---
1
F300
0
"
219D
Breaker Flashover 1 Status Closed C
0 to 4294967295
---
1
F300
0
"
219F
Breaker Flashover 1 Voltage Pickup Level
0 to 1.5
pu
0.001 F001
850
"
21A0
Breaker Flashover 1 Voltage Difference
Pickup Level
0 to 100000
V
1
F060
1000
"
21A2
Breaker Flashover 1 Current Pickup Level
0 to 1.5
pu
0.001 F001
600
"
21A3
Breaker Flashover 1 Pickup Delay
0 to 65.535
s
0.001 F001
100
"
21A4
Breaker Flashover 1 Supervision Phase A
0 to 4294967295
---
1
F300
0
"
21A6
Breaker Flashover 1 Supervision Phase B
0 to 4294967295
---
1
F300
0
"
21A8
Breaker Flashover 1 Supervision Phase C
0 to 4294967295
---
1
F300
0
"
21AA
Breaker Flashover 1 Block
0 to 4294967295
---
1
F300
0
"
21AC
Breaker Flashover 1 Events
0 to 1
---
1
F102
0 (Disabled)
"
21AD
Breaker Flashover 1 Target
0 to 2
---
1
F109
0 (Self-Reset)
"
21AE
Reserved (4 items)
---
---
---
F001
0
B30, C60, D60,
F60, G60, L60,
L90, M60, T60
21B2
...Repeated for Breaker Flashover 2
Bus Actuals (Read Only) (6 Modules)
B90
21D0
Bus Zone 1 Differential Magnitude
0 to 999999.999
A
0.001 F060
0
"
21D4
Bus Zone 1 Differential Angle
-359.9 to 0
degrees 0.1
F002
0
"
21D5
Bus Zone 1 Restraint Magnitude
0 to 999999.999
A
0.001 F060
0
"
21D7
Bus Zone 1 Restraint Angle
-359.9 to 0
degrees 0.1
F002
0
"
21D8
Bus Zone 1 Maximum CT
0 to 50000
---
1
F060
1
"
21DA
Reserved (4 items)
---
---
---
F001
0
"
21DE
...Repeated for Bus Zone 2
Products
Address Register name
Range
Units
Step
Format
Default
Summary of Contents for UR series
Page 5: ...TABLE OF CONTENTS UR SERIES COMMUNICATIONS GUIDE v INDEX...
Page 6: ...vi UR SERIES COMMUNICATIONS GUIDE TABLE OF CONTENTS...
Page 20: ...1 14 UR SERIES COMMUNICATIONS GUIDE FOR FURTHER ASSISTANCE CHAPTER 1 INTRODUCTION 1...
Page 216: ...2 196 UR SERIES COMMUNICATIONS GUIDE MEMORY MAP CHAPTER 2 MODBUS COMMUNICATION 2...
Page 428: ...A 2 UR SERIES COMMUNICATIONS GUIDE REVISION HISTORY APPENDIX A MISCELLANEOUS A...