CHAPTER 2: MODBUS COMMUNICATION
MEMORY MAP
UR SERIES – COMMUNICATIONS GUIDE
2-79
2
"
65D9
Power Swing Detect Quad Reverse Middle 0.1 to 500
ohms
0.01
F001
6000
"
65DA
Power Swing Detect Quad Reverse Outer
0.1 to 500
ohms
0.01
F001
7000
"
65DB
Power Swing Detect Outer Right Blinder
0.1 to 500
ohms
0.01
F001
10000
"
65DC
Power Swing Detect Outer Left Blinder
0.1 to 500
ohms
0.01
F001
10000
"
65DD
Power Swing Detect Middle Right Blinder
0.1 to 500
ohms
0.01
F001
10000
"
65DE
Power Swing Detect Middle Left Blinder
0.1 to 500
ohms
0.01
F001
10000
"
65DF
Power Swing Detect Inner Right Blinder
0.1 to 500
ohms
0.01
F001
10000
"
65E0
Power Swing Detect Inner Left Blinder
0.1 to 500
ohms
0.01
F001
10000
"
65E1
Power Swing I2 Supervision Enable
0 to 4294967295
---
1
F300
0
"
65E3
Power Swing I2 Supervision
0.05 to 30
pu
0.001 F001
200
Bus Configuration (Read/Write Setting) (6 Modules)
B90
65EE
Bus Zone x Status (24 items)
0 to 4294967295
---
1
F300
0
Motor Setup (Read/Write Setting)
M60
6600
Thermal Model Motor FLA
0.05 to 1
pu
0.001 F001
1000
"
6601
Thermal Model Motor Overload Factor
1 to 1.5
---
0.01
F001
100
"
6602
Thermal Model Line Source
0 to 5
---
1
F167
0 (SRC 1)
"
6603
Thermal Model Motor Offline
0 to 4294967295
---
1
F300
0
"
6605
Thermal Model RTD 1
0 to 48
---
1
F151
0 (NONE)
"
6606
Thermal Model RTD 2
0 to 48
---
1
F151
0 (NONE)
"
6607
Thermal Model RTD 3
0 to 48
---
1
F151
0 (NONE)
"
6608
Thermal Model RTD 4
0 to 48
---
1
F151
0 (NONE)
"
6609
Thermal Model RTD 5
0 to 48
---
1
F151
0 (NONE)
"
660A
Thermal Model RTD 6
0 to 48
---
1
F151
0 (NONE)
"
660B
Motor Emergency Restart
0 to 4294967295
---
1
F300
0
"
660D
Motor Nameplate Voltage
100 to 50000
V
1
F001
600
"
660E
Speed 2 Motor Protection
0 to 1
---
1
F102
0 (Disabled)
"
660F
Speed 2 Motor Switch
0 to 4294967295
---
1
F300
0
"
6611
Speed 2 Switch 2-1 Delay
0 to 600
s
0.01
F001
500
"
6612
Speed 2 Motor Source
0 to 5
---
1
F167
0 (SRC 1)
"
6613
Speed 2 Motor FLA
0.05 to 1
pu
0.001 F001
1000
Bus Configuration (Read/Write Setting) (6 Modules)
B90
661E
...Repeated for Bus Zone 2
Thermal Model Actual Values (Read Only)
M60
6630
Thermal Model Motor Status
0 to 3
---
1
F098
1 (Starting)
"
6631
Thermal Model Capacity Used
0 to 100
%
1
F001
0
"
6633
Trip Time On Overload
0 to 10000
---
1
F001
0
"
6634
Thermal Model Lockout Time
0 to 65000
min
1
F001
0
Thermal Model Actuals (Read Only)
M60
6638
Thermal Model Load
0 to 40
x FLA
0.01
F001
0
"
663A
Thermal Model Motor Unbalance
0 to 100
%
1
F001
0
"
663B
Thermal Model Biased Motor Load
0 to 40
x FLA
0.01
F001
0
"
663C
Start/Hour Lockout Time
0 to 65000
min
1
F001
0
"
663D
Time-Between-Starts Lockout Time
0 to 65000
min
1
F001
0
"
663E
Restart Delay Lockout Time
0 to 50000
s
1
F001
0
"
663F
Total Motor Lockout Time
0 to 65000
min
1
F001
0
Field Ground Actual Values (Read Only)
G60
6640
Field Ground Resistance
0 to 20000
kOhm
0.001 F003
20000000
Products
Address Register name
Range
Units
Step
Format
Default
Summary of Contents for UR series
Page 5: ...TABLE OF CONTENTS UR SERIES COMMUNICATIONS GUIDE v INDEX...
Page 6: ...vi UR SERIES COMMUNICATIONS GUIDE TABLE OF CONTENTS...
Page 20: ...1 14 UR SERIES COMMUNICATIONS GUIDE FOR FURTHER ASSISTANCE CHAPTER 1 INTRODUCTION 1...
Page 216: ...2 196 UR SERIES COMMUNICATIONS GUIDE MEMORY MAP CHAPTER 2 MODBUS COMMUNICATION 2...
Page 428: ...A 2 UR SERIES COMMUNICATIONS GUIDE REVISION HISTORY APPENDIX A MISCELLANEOUS A...