GE Multilin
T60 Transformer Protection System
4-25
4 HUMAN INTERFACES
4.3 FACEPLATE INTERFACE
4
b) HIERARCHY
The setting and actual value messages are arranged hierarchically. The header display pages are indicated by double
scroll bar characters (
), while sub-header pages are indicated by single scroll bar characters (
). The header display
pages represent the highest level of the hierarchy and the sub-header display pages fall below this level. The MESSAGE
UP and DOWN keys move within a group of headers, sub-headers, setting values, or actual values. Continually pressing
the MESSAGE RIGHT key from a header display displays specific information for the header category. Conversely, contin-
ually pressing the MESSAGE LEFT key from a setting value or actual value display returns to the header display.
c) EXAMPLE MENU NAVIGATION
4.3.8 CHANGING SETTINGS
a) ENTERING NUMERICAL DATA
Each numerical setting has its own minimum, maximum, and increment value associated with it. These parameters define
what values are acceptable for a setting.
HIGHEST LEVEL
LOWEST LEVEL (SETTING VALUE)
SETTINGS
PRODUCT SETUP
SECURITY
ACCESS LEVEL:
Restricted
SETTINGS
SYSTEM SETUP
ACTUAL VALUES
STATUS
Press the MENU key until the header for the first Actual Values page appears. This
page contains system and relay status information. Repeatedly press the MESSAGE
keys to display the other actual value headers.
SETTINGS
PRODUCT SETUP
Press the MENU key until the header for the first page of Settings appears. This page
contains settings to configure the relay.
SETTINGS
SYSTEM SETUP
Press the MESSAGE DOWN key to move to the next Settings page. This page con-
tains settings for System Setup. Repeatedly press the MESSAGE UP and DOWN
keys to display the other setting headers and then back to the first Settings page
header.
SECURITY
From the Settings page one header (Product Setup), press the MESSAGE RIGHT
key once to display the first sub-header (Security).
ACCESS LEVEL:
Restricted
Press the MESSAGE RIGHT key once more and this will display the first setting for
Security. Pressing the MESSAGE DOWN key repeatedly will display the remaining
setting messages for this sub-header.
SECURITY
Press the MESSAGE LEFT key once to move back to the first sub-header message.
DISPLAY
PROPERTIES
Pressing the MESSAGE DOWN key will display the second setting sub-header asso-
ciated with the Product Setup header.
FLASH MESSAGE
TIME: 1.0 s
Press the MESSAGE RIGHT key once more and this will display the first setting for
Display Properties.
Summary of Contents for UR T60
Page 10: ...x T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 14: ...xiv T60 Transformer Protection System GE Multilin 0 1 BATTERY DISPOSAL 0 BATTERY DISPOSAL 0 ...
Page 34: ...1 20 T60 Transformer Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 436: ...5 298 T60 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 678: ...C 30 T60 Transformer Protection System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Page 688: ...D 10 T60 Transformer Protection System GE Multilin D 1 IEC 60870 5 104 PROTOCOL APPENDIX D D ...
Page 700: ...E 12 T60 Transformer Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...