Programming Site Data
2-9
March 2004
Entering the Pipe
Material (cont.)
.
4.
The next required parameter is either the outside diameter
(OD)
or
the circumference
(OD x
π).
Scroll to the measured parameter and
press [ENT]. For either measurement, enter the desired value and
press [ENT].
Note:
Obtain the required information by measuring either the pipe
outside diameter (OD) or circumference at the transducer
installation site. The data may also be obtained from standard
pipe size tables found in
Sound Speeds and Pipe Size Data
(914-004).
5.
The meter also requires the
Wall Thickness (WT)
. Scroll to the WT
option, and press [ENT]. Use the arrow keys to enter the known
thickness, and press [ENT].
Note:
To obtain an accurate pipe wall thickness measurement, use
an ultrasonic thickness gauge.
Table 2-1: Preprogrammed Pipe Materials
Pipe Material Category
Specific Material
Al - Aluminum
Rolled or None
Brass
None
Cu - Copper
Annealed, Rolled or None
CuNi - Copper/Nickel
70% Cu 30% Ni or 90% Cu 10% Ni
Glass
Pyrex, Flint, or Crown
Gold
Hard-drawn
Inconel
None
Iron
Armco, Ductile, Cast, Electrolytic
Monel
None
Nickel
None
Plastic
Nylon, Polyethylene, Polyproplene,
PVC (CPVC), or Acrylic
Steel
Carbon Steel, Mild or Stainless Steel
Tin
Rolled
Titanium
None
Tungsten
Annealed, Carbide, Drawn
Zinc
Rolled
Summary of Contents for UTX878 Ultrasonic
Page 2: ...iii March 2004 The UTX878 Flow Transmitter and Transducers ...
Page 8: ...Chapter 1 ...
Page 20: ...March 2004 Installation 1 11 Figure 1 5 UTX878 Outline and Installation Dwg 712 1196 rev 2 ...
Page 22: ...March 2004 Installation 1 13 Figure 1 7 UTX878 Wiring Diagram Dwg 702 528 rev 2 ...
Page 23: ...Chapter 2 ...
Page 45: ...Chapter 3 ...
Page 52: ...Chapter 4 ...
Page 60: ...Chapter 5 ...
Page 65: ...Chapter 6 ...
Page 75: ...Chapter 7 ...
Page 80: ...Appendix A ...
Page 85: ...Appendix B ...
Page 86: ...CE Mark Compliance Introduction B 1 EMC Compliance B 1 ...
Page 88: ...Appendix C ...
Page 89: ...Data Records Site Data C 1 ...
Page 93: ...Appendix D ...
Page 94: ...Service Record Introduction D 1 Data Entry D 1 Diagnostic Parameters D 3 ...