Secure Perfect 6.1.1 User Manual
177
•
Down: Select a field and click to lower the priority of this field, which determines how the
groups will be sorted.
Global Edition Regional Configuration Rules
This topic addresses administration and behavior of a successful Secure Perfect Global Edition system.
Particular functions in the Global Edition must be handled locally, at the Regional level. The following
table is an overview of administrative functions and links to forms where configuration and behavior must
be considered.
Secure Perfect
Form
Updates Allowed
in Remote
Regions?
Deletions
Allowed in
Remote
Regions?
Comments
Access Rights Form
– Readers Only
Yes Yes
Adding or deleting readers from an access
right for a local Region or remote Region
:
The micros get updated with the correct
reader information in both cases
Digital Output Groups, Elevators, and
Zone assignment for access right must
wait until replication interval to update the
remote database and then perform a
database download to micros in the
remote Region.
Alarm Form
No (See
Comments)
N/A
Updating in a Remote Region
: Updates to
nonmicro alarms (such as CCTV, Camera,
and DVR alarms) are allowed. Updates to
devices directly controlled by I/O boards in
the micro (such as digital inputs and
readers) are not allowed. They must be
updated at a local Regional level.
Alarm Group Form
No
N/A
Badge Alias Form
Yes
Yes
No action required.
CCTV Alarm Form
Yes
Yes
No action required.
Client Form
Yes
Yes
Backup Clients tab, Assign micro phone
numbers
No action required.
Digital Input Form
No
N/A
Digital Output Form
No
N/A
Digital Output
Group Form
No No
Digital Video
Recorder
Yes Yes
Editing a DVR in a remote Region
: Wait for
replication to occur before changes take
effect. If user changes the host name to a
remote client, wait for replication to occur
and then restart the hosting client’s
services.
Adding a DVR in a remote Region
: Wait for
replication to occur and then restart
services on the remote client.
Elevator Form
Yes
Yes
Editing an elevator in a remote Region
:
Edits will not be applied until replication
occurs on the remote database. After
replication, the operator must manually
initiate a database download from the
Micro Utility Form
in order for changes to