13.5.6
Using the Ethernet Station Manager Function
CPUE05 provides local Station Manager operation via Port 1. This port can be configured
for either CPU serial communications (SNP, RTU, Serial I/O) or local Station Manager
use. While Port 1 is configured as a local Station Manager, it cannot be used for CPU
serial communications or firmware loading. However, if the port is configured as a CPU
port instead (the default setting), it can temporarily be forced to local Station Manager
operation using the Restart pushbutton (or using the
chport1
Station Manager command).
The CPUE05 also supports remote Station Manager operation over the Ethernet network
via UDP protocol. With UDP protocol, the remote station is addressed via an IP address.
Unlike some Series 90 Ethernet products, CPUE05 cannot send or receive remote Station
Manager messages that have been sent to a specified MAC address.
For a detailed description of Station Manager functions, refer to the
VersaMax PLC
Ethernet Station Manager User Manual
(GFK-1876).
268
GFK-1503E
VersaMax PLC User Manual
For public disclosure
Summary of Contents for VersaMax PLC
Page 16: ...Notes 16 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 38: ...Notes 38 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 50: ...Notes 50 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 92: ...Notes 92 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 112: ...Notes 112 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 224: ...Notes 224 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 292: ...Notes 292 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 316: ...Notes 316 GFK 1503E VersaMax PLC User Manual For public disclosure ...
Page 317: ......