12.
Reinstall evaporator screw in the top left side. Grasp
evaporator at the bottom with both hands, push up to
the ceiling, engage the eyelet screw and push as far
left as possible. Tighten eyelet screw to hold in place.
Reinstall foam block in the left rear corner.
■
■
13.
Maintain at least 3/16" clearance between evaporator
coils and styrofoam on the right side wall to prevent
moisture transfer.
Prepare Machine Compartment
■
■
14.
Check PermaGum and/or RTV sealer where the heat
exchanger enters the evaporator wall. Check wires in
the grommet, push PermaGum between the wires for
a complete seal.
■
■
15.
Cut tubing length on the drain pan hose at designated
marks for 36" and 42" wide models. Hose is sized to fit
48" wide models.
■
■
17.
Push drain pan assembly up and against the bottom of
the evaporator. The bottom of the styrofoam drain pan
must be evenly aligned with the bottom of the insulating
styrofoam on the right side wall. Use insulated tape
along the bottom to seal gap between these pieces.
■
■
18.
Secure drain hose in the machine compartment with
original clamps. Check to be sure the hose will
discharge into the compressor drain pan.
■
■
19.
Secure new ground wire to front of freezer cabinet in
the same location as original wire.
■
■
20.
Note:
Orange jumper wire not used on models pro-
duced after Oct. 1994. Connect Orange wire from the
evaporator fan motor to the stack terminal of the
orange jumper wire.
■
■
21.
Connect one lead of the drain pan heater to the
Yellow
female harness connector. Connect other lead to the
Orange jumper wire female connector (bullet end).
Route jumper wire towards the right rear corner and
bundle with wire tie. To avoid interference with
evaporator fan, attach the other wire, loosely, to the
heat exchanger with a wire tie.
HEATER
WIRES
DRAIN PAN
EVAPORATOR
PAN FOAM
HOUSING
HOSE CLAMP
DRAIN TUBE
INSULATOR
DONUT RING
522-08A
GROUND
WIRE
MIS-ALIGNED
(FOAM HOUSING
BELOW SIDE FOAM)
ALIGNED
(FOAM HOUSING
FLUSH WITH
SIDE FOAM)
INCORRECT
CORRECT
522008N
522-08B
STACK
TERMINAL
14" JUMPER WIRE
FEMALE BULLET
CONNECTOR
HEATER
WIRES
WIRE TIE
ORANGE
JUMPER WIRE
ORANGE
JUMPER
WIRE
PINK WIRES
(FEMALE
CONNECTOR)
522-08O
REAR VIEW
Installation Instructions
Page 3 of 4
70836-00
■
■
11.
Press insulation pieces onto the top and front side
plates on the left side of the evaporator. Press
insulation piece on rear plate (if not present). Open
the eyelet slot for the mounting screw.
■
■
16.
Insert end of new hose through the evaporator
compartment wall and into the machine compartment.
OPEN EYELET
SCREW SLOT
522-08ZZ
INSULATION
TAPE
PLACE
INSULATION
TAPE ON
FRONT AND
BACK SIDE