D
GB
F
E
7
96031-11.2011-DGbFEI
2
|
Product description
2.2 Name plate
(example)
2.3 Type key
(example)
¹
)
HG - Hermetic Air-Cooled (air-cooled)
Fig. 3
/
Transkritical
CO
2
version
Number of poles
Swept volume
Size
Ester oil charge
Series¹
)
HA
2 110- 4 CO
2
X
T
1
Type designation
2
Machine number
3
maximum operating current
4
Starting current (rotor blocked)
Y: Part winding 1
YY: Part winding 1 and 2
5
ND (LP): max. permissible operating
pressure
(g)
Low pressure side
HD (HP): max. permissible operating
pressur
e
(g)
High pressure side
Observe the limits of
application diagrams!
50 Hz
60 Hz
6
Voltage, circuit, frequency
7
Nominal rotation speed
8
Displacement
9
Voltage, circuit, frequency
10 Nominal rotation speed
11 Displacement
12 Oil type filled at the factory
13 Terminal box protection type
Electrical accessories can change
the IP protection class!
}
}
1
2
3
4
5
100/150 bar
HAX2/110-4 CO
2
T
AS30046A002
26,7 A
380-420V Y/YY
9,66
440-480V Y/YY
1750
11,66
65
13
12
7
11
6
10
8
9
CO2,C 85 E
Y: 110 A Y: 141 A
GEA Bock GmbH
72636 Frickenhausen, Germany