The following tables apply to the Torus and the Chemitorus
Temperature
class
Maximum surface temperature
Proper operating conditions
T5
≤100 °C
Operating and medium temperatures - maximum 65 °C
Ambient temperature: maximum 75 °C (minimum °C)
T6
≤85 °C
Operating and medium temperatures - maximum 60 °C
Ambient temperature: maximum 60 °C
2.3.2
Pressure
The proper operational pressures are given in the following tables. The specified
operating pressures must be observed and monitored.
Hint!
The specified pressure is the pressure at the cleaning head and not at
the pump.
Cleaner
Operating pressure range
Turbo SSB 40
Turbo SSB 75
Turbo SSB 125
2 - 5 bar
2 - 10 bar
2 - 6 bar
Turbodisc & Chemidisc
1 - 5 bar
Torus & Chemitorus
1 - 5 bar
Sanidisc
2 - 4 bar
Sanitor
3 – 20 bar*
* When using a cleaning pressure >12, using solvents with low conductivity,
separate parameters acc. to TRGS-727:2016 must be observed, see Section 4.2,
Page 17.
2.3.3
Flow rate
For the safe operation of the rotating cleaners it must be ensured that the cleaner
is operated only with a supply of liquid. .
For safer operation, the safety instructions and operating parameters of
TRGS-727: 2016, see Section 4.2, Page 17.
Hint!
*pressure at the cleaning head, NOT at the pump.
** All pressure data [bar] are for overpressure [bar
g
] unless this is
specifically described otherwise.
Working
pressure
[bar]
Flow rate [m
3
/h]
Turbo SSB 40
Turbo SSB 75
Turbo SSB 125
BSP/NPT
Pin Fix
BSP/NPT
Pin Fix
BSP/NPT
Pin Fix
2
2.1
2.3
3.6
4
12
14
3
2.6
2.8
4.5
4.8
15
17
Safety
Operating Conditions
430BAL013060EN_4
08.09.2020
11