12. Maintenance
12.1 Maintenance schedule
In order to prevent faults or malfunctions, you are advised periodically to examine certain essential points of your
GENEGLACE.
The user guide mentions the current service and inspection operations that can be performed. To this must be added :
Maintenance
Operation
Recommended
frequency
daily
Routine
inspection
Compressor oil level, icing of inlet valve, temperature of casing (Base cools down
when stopped), spraying of the wall of the drum, accumulation of ice on the reamer,
bearings, regular consumption of salt or salt solution.
Recharge standard salt dosing system
Or
Filling up the brine containers for the dosing pump
depending on
consumption
Cleaning standard salt dosing system
monthly
Cleaning water system
Base, tanks, valve operation
weekly
Grease bearings ( use greasing pump)
Central shaft and reamer bearings
(Food compatible grease fulfils :
NSF.H1 standard
), consult us if necessary
every three
months
Checking operating pressures
every three
month
Checking operation of the torque limiter switch and the condition of the wipers
every three
month
Examining the gearbox
(for traces of oil)
occasionally
Examining the internal wall of the drum for scaling
Presence of a whitish deposit on the dry wall
occasionally
To control the state of refrigerating pipings as well as the insulation
(oxidation -
attacks chemical ---) to cure it if necessary
Annual