24
D
GB
F
E
I
Ru
09637-06.2015-DGbFEIRu
7.1 Preparation
7.2 Work to be carried out
7
|
Maintenance
In order to guarantee optimum operational reliability and service life of the compressor,
we recommend
carrying out servicing and inspection work at regular intervals:
Oil change:
-
not mandatory for factory-produced series systems.
-
for field installations or when operating near the application limit: for the first time after 100
to 200 operating hours, then approx. every 3 years or 10,000 - 12,000 operating hours.
Dispose of used oil according to the regulations; observe national regulations.
Annual checks:
Oil level, leak tightness, running noises, pressures, temperatures, function of
auxiliary devices such as oil sump heater, pressure switch.
WARNING! Before starting any work on the compressor:
Switch off the compressor and secure it to prevent a restart.
Relieve compressor of system pressure.
Prevent air from infiltrating the system!
After maintenance has been performed:
Connect safety switch.
Evacuate compressor.
Release switch-on lock.
6.8 Connection of oil level regulator
The connection "O" is provided for installing an oil level regulator. A corresponding adapter must be
obtained from the trade.
6
|
Commissioning
Only use genuine GEA Bock spare parts!
7.3 Spare parts recommendation
HG22P / ...
125-4 (S)
160-4 (S)
190-4 (S)
Designation
Ref. No.
Ref. No.
Ref. No.
Set of gaskets
80313
Valve plate kit
80305
80306
Oil pump kit
08324