Safety
Instructions for the Safe Operation
14
Operating Instructions GEA Orbital Cleaner Jumbo 6
Edition 2016-05-24
For maintenance and repair, the following principles apply:
•
Observe the intervals specified in the maintenance schedule.
•
Only allow qualified staff to carry out maintenance or repair work on the
cleaner.
•
Before starting any maintenance or repair work, the cleaner must be
switched off and secured against being switched back on. Work may
only be started once any residual energy has been discharged.
•
Block access for unauthorized persons. Put up notice signs which draw
attention to the maintenance or repair work going on.
•
Wear suitable protective clothing.
•
Only use suitable and undamaged tools to carry out maintenance work.
•
When replacing parts only use approved, fully functional load lifting
devices and lifting accessories which are suitable for the intended
purpose.
•
Before setting the unit back into operation refit all safety devices as origi-
nally provided in the factory. Then check that all safety devices are
working correctly.
•
Check pipes are firmly secured, also check for leaks and damage.
•
Check that all emergency stop devices are working correctly.
Disassembly
For disassembly, the following principles apply:
•
Only allow qualified staff to disassemble the cleaner.
•
Before starting disassembly, the cleaner must be switched off and
secured against being switched back on. Work may only be started once
any residual energy has been discharged.
•
Disconnect all power and utility lines.
•
Markings, e.g. on lines, must not be removed.
•
Mark the lines (if unmarked) prior to disassembly to ensure they are not
confused when re-assembling.
•
Protect open line ends with blind plugs against ingress of dirt.
•
Pack sensitive parts separately.