Explanation of the items in the order code
Item in the order code
Designation
Explanation
/UC
Certification UL/CSA
For indoor use and only
for the type of interface
connection:
A - AS-interface
B - 24 V DC
D - DeviceNet
I - IO-Link
/CD
UL 121201 -
Nonincendive Electrical
Equipment for Use in
Class I and II, Division 2
and Class III, Divisions 1
and 2 Hazardous
(Classified) Locations.
CSA C22.2 No. 213-17 -
Nonincendive electrical
equipment for use in
Class I and II, Division 2
and Class III, Divisions 1
and 2 hazardous
5.2
Technical data
Refer to the following tables for the key technical data of the control top:
Technical data: temperatures and compressed air supply
Designation
Description
Ambient temperature
-20 to +55 °C
Control air
acc. to ISO 8573-1
- Solid particle content:
Quality class 6 (recommended)
Particle size max. 5mu
Particle density max. 5 mg/m
3
- Water content:
Quality class 4 (max.)
Dew point +3°C
If the unit is used at higher altitudes or
at low ambient temperatures, the dew
point must be adapted accordingly.
- Oil content:
Quality class 3
preferably oil free,
max. 1 mg oil to 1 m
3
air
Technical data
Technical data
430BAL010699EN_6
26
17.03.2022
Summary of Contents for T.VIS A-15
Page 6: ...430BAL010699EN_6 6 17 03 2022...