29
Connection
Pneumatic Connections
Connection
Establishing Hose Connections
To ensure reliable operation, the compressed air hoses must be cut exactly square.
Requirement:
A hose cutter
Carry out the following steps:
1.
Shut off the compressed air supply.
2.
Use the hose cutter to cut the pneumatic hoses square.
3.
Push the air hose into the air connector (P) on the control top.
4.
Re-open the compressed air supply.
Done
Pneumatic Connections
Control Top without or with 1 Solenoid Valve
Control Air Hoses
E1
Exhaust air of the main stroke Y1 (sound absorber or exhaust air throttle, optional)
Connection E1 must not be closed!
E2
Safety vent against excess pressure and exhaust air of lifting actuators Y2 and Y3
Connection E2 must not be closed!
P
Central air supply with integrated filter (optional supply air throttle)