57
Setting into Operation
Adjusting the Sensor in the Control Top
3.
Move the sensor with the adjusting screw (1) in the direction of the upper switching
edge (4) of the switching range (3) until LED A goes out and LED B flashes yellow.
Setting the switch-
point
Carry out the following steps:
1.
Moving the switchpoint downwards
All a/m valves/sprayers except for VESTA valves:
1 turn
in counter-clockwise
direction
VESTA valves:
0.5 turns
in counter-clockwise direction
Light-emitting diode A at the interface module lights up green.
2.
Tighten the locking screw (2), torque 1 Nm (0.7 lbft).
The start position of the valve disk has been adjusted.
NOTE
Turning the adjusting screw (1) clockwise moves the sensor upwards, turning counter-
clockwise moves the sensor downwards!