83
Mounting the Control Top to Different Valves
Fitting to an ASEPTOMAG Valve
Fitting to an ASEPTOMAG Valve
Requirement:
Pay attention not to kink the air hoses when mounting the control top.
IMPORTANT NOTE
The permanent magnet on the switch bar is fragile.
Damage to the permanent magnet.
Protect the permanent magnet against impact stress.
IMPORTANT NOTE
Magnetic fields resulting from the permanent magnet on the switch bar.
Magnetic fields can delete data carriers and affect or destroy electronic or mechanical
components.
Protect the components against the magnetic fields from the switch bar.
Carry out the following steps:
1.
Place the T.VIS mounting base (M), with O-rings (M1), on the actuator (A.4) and
secure it with four M5 screws (M.2).
2.
Screw the switch bar (4), mat. No. 221-589.87, into the piston rod (A4.1) and tighten
using an open end spanner, tightening torque 3 Nm.
3.
Fit the control top (B) over the switch bar (4) and on the actuator.
4.
Tighten the clamp connection (5) and screws (39) to a torque of 1 Nm.
5.
Align the pneumatic and electrical connections in accordance with the valve block
configuration.