Dismantling the Control Top into its Components
90
Operating Instructions · Control Top T.VIS
®
M-15
Edition 2017-10-16
Removing the Solenoid Valves and the Control Plate
Requirement:
Observe the assignment of cables between the solenoid valve and the interface
module – solenoid valve Y1 to be connected to terminal Y1.1/Y1.2.
Only use solenoid valve types specified in chapter “Technical Data“ (page 100).
CAUTION
Risk of burns from the solenoid valve as a result of long switch-on time and high
ambient temperature.
Allow to cool before dismantling.
Carry out the following steps:
1.
Disconnect the cables of the solenoid valve from the terminals of the interface
module (43).
2.
Undo the screws (63.1) and separate the solenoid valve (63) from the pneumatic
block (8).
3.
Undo the screws (65.1) and separate the control plate (65) from the pneumatic block
(8).
Done
NOTE
Fit the solenoid valves and control plate in the reverse order.
Lightly grease the seals before fitting them to prevent them from falling out!