6.3.1
Control Top with Solenoid Valves
Fig.9:
Control top (standard variant in IP66), front
Fig.10:
Control top, rear
E2
Safety vent against excess pressure
P
Central air supply with integrated filter at solenoid valve NC
via supply air throttle (75)
N
Exhaust air of the main stroke via solenoid valve NC and NO
via exhaust throttle (75)
Y1
Air connection for external main stroke connection
with sealing plug
Caution!
Compressed air outlet
Control air can be present at the plugs for the air connections!
► Before removing a sealing plug, make sure that the respective air
connection is pressure-free!
Basic setting of the throttle valve:
®
using a slotted screwdriver (75.1), turn the throttle clockwise to close it and
counterclockwise by 2 turns to open it! Can be adjusted to the process
conditions.
Hint!
On most of the GEA Tuchenhagen valve types, solenoid valve Y1
internally guides the main control air through the switch bar into the
main actuator. The external air connection Y1 is provided in addition.
Assembly and installation
Pneumatic connections
430BAL010747EN_3
26
24.07.2020
Summary of Contents for T.VIS P-15